background image

Installation 

P.O. Box 309

Menomonee Falls, WI 53052 USA

800 BRADLEY (800 272 3539)

+1 262 251 6000

bradleycorp.com

S93-572 – AST4  

S93-573 – TouchTime  

S93-574 – Infrared

Stainless Steel Wall-Hung 

BradMate™ Washfountain 

(Standard* & Juvenile Height) 

* Standard Height is ADA Compliant

215-1595 Rev. E; ECN 17-00-014
© 2017 Bradley
Page 1 of 17 

9/28/2017

S93-572
S93-573

S93-574

Table of Contents

Supplies Required  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Pre-installation information   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
BradMate Dimensions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Step 1 Rough-Ins   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Step 2 Mount Washfountain to Wall   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Step 3 Assemble the Trap  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
Step 4 Connect Supplies .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
Step 5 .1 Test the Installation — AST4   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9
Step 5 .2 Electrical Connections — TouchTime  .  .  .  .  .  .  .  .  .  .  .  . 10
Step 5 .3 Electrical Connections — Infrared   .  .  .  .  .  .  .  .  .  .  .  .  .  . 11
Step 6 Adjust Temperature with Running Water   .  .  .  .  .  .  .  .  .  .  . 12
Step 7 Complete Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12
Thermostatic mixing valve troubleshooting  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 13
Parts List — Aerator Assembly  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14
Cleaning and maintenance instructions for stainless steel  .  .  . 14
Metering Air Valve Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15
Troubleshooting - Metering Air Valve .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 16
Troubleshooting - Solenoid Valve   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 17

Содержание BradMate S93-572

Страница 1: ...llation information 3 BradMate Dimensions 4 Step 1 Rough Ins 5 Step 2 Mount Washfountain to Wall 6 Step 3 Assemble the Trap 7 Step 4 Connect Supplies 8 Step 5 1 Test the Installation AST4 9 Step 5 2 Electrical Connections TouchTime 10 Step 5 3 Electrical Connections Infrared 11 Step 6 Adjust Temperature with Running Water 12 Step 7 Complete Installation 12 Thermostatic mixing valve troubleshooting...

Страница 2: ... have been flushed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction Hardware supplied by installer must be appropriate for wall construction Wall anchors used must have a minimum pull out rating of 1 000 lbs CAUTION Water supply requires a flowing pressure of at least 20 psi but no greater than 80 psi The AccuZone Infrared and Touc...

Страница 3: ...red water from one aerator with a push button for 15 seconds Each valve uses less than half the maximum amount of hot water allowed by the ANSI ASHRAE IES 90A 1980 Standard Solenoid valve An electronically controlled solenoid valve serves as the metering mechanism Few moving parts provide reliable metering performance and the solenoid is unaffected by chemicals and minerals often present in munici...

Страница 4: ...4 S93 572 S93 573 S93 574 Installation A D A C O M PLIANT BradMate Dimensions Subtract 4 101 from this dimension for juvenile height model Standard height is ADA compliant 27 3 8 695 18 1 2 470 9 1 8 232 18 1 2 470 6 13 16 173 37 15 16 964 34 864 mm ...

Страница 5: ...for Supplies Stub Out 1 Hot Cold 110 V GFI Electrical Outlet 31 3 4 806 22 1 2 572 3 76 2 3 4 70 1 1 2 Drain through Wall Stub Out 1 25 1 2 648 Center Line of Bradmate Finished Floor mm Compliance and conformity to local codes and ordinances is the responsibility of the installer WARNING Flush the supply lines before making connections Debris in supply lines will cause the valves to malfunction WA...

Страница 6: ...all three 1 4 wall anchors supplied by installer into the wall at dimensions shown B Install eight 10 wall anchors supplied by installer into the wall at dimensions shown C Mount center bracket to wall with bolt and washer supplied by installer D Hang bowl backsplash assembly on center bracket E Fasten the assembly to wall on each side of bowl bolts supplied by installer 25 1 4 641 12 5 8 321 Cent...

Страница 7: ...er washers included with the P trap into the tube ends E Connect one end of the P trap to the waste elbow and the other end to the 1 1 2 drain pipe supplied by installer The drain pipe should already be stubbed out 1 from the wall at the location F Insert the strainer into the drain plug opening inside the bowl and push the strainer firmly down into place FASTEN WITH SCREW PROVIDED 8 32 Screw 160 ...

Страница 8: ... inlet of the Navigator marked with the letter H must be connected to hot water rough in The letter H on the Navigator Mixing Valve indicates hot water supply inlet The thermostatic mixing valve requires at least 115 F water from the hot water side for proper operation As with all lavatories there will be a delay in obtaining warm water If the hot water is too far away from the washfountain a circ...

Страница 9: ...test the unit and check for leaks B Press the two push buttons several times to purge air from the lines 5 1 1 Adjust Air Metering Valve A Unscrew the timer cover and use a screwdriver to tighten or loosen the timer Turning the timer clockwise increases the time turning the timer counterclockwise decreases the time Be careful not to overtighten as the timer seat can be damaged B Continue to adjust...

Страница 10: ...ify activation Navigator Mixing Valve Green Tubing Left Button Right Button TouchTime Switch S83 368 Washer 142 088 Nut 5 16 18 161 036 Nut 1 4 20 161 026 Washer 142 002BS Solenoid Ganged Valve Assy S08 2402TMA Red Tubing Compression Nuts Green Supply Tube Red Supply Tube TouchTime Module S83 360 Each female jack plugs into the male jack port of the TouchTime module S83 360 2 Way Splitter 251 027A...

Страница 11: ...Turn on the electrical power and pass your hand in front of each sensor to verify activation Power Adapter 261 147A Left Sensor Right Sensor Left Green Tubing Right Red Tubing Nut 5 16 18 161 036 Washer 142 088 Solenoid Ganged Valve Assy S45 3485 Washer 142 002BS Nut 1 4 20 161 026 Connect to Right Station Connect to Left Station Power Jack from Harness S83 367B WARNING The infrared control must b...

Страница 12: ...owl covers over the piping valve assembly underneath the bowl B Bolt the bowl covers to the wall with four 10 bolts supplied by installer Secure the bowl covers to the tabs on the underside of the bowl using the 10 32 screws provided C Attach the trap cover to the wall using four 10 bolts supplied by installer 107 360 Screw Hole Attach Bowl Cover to Bowl Screw Hole Attach Bowl Cover to Bowl 107 35...

Страница 13: ...emperature Be sure to close the appropriate shut off valves prior to disassembly of the valve and reopen the valves after inspection and repair is complete Problem Cause Solution External leaks Damaged cartridge or O rings Replace cartridge with part number 269 1927 Improper water temperature or temperature fluctuation Hot water supply is not 10 above desired set point Increase hot water supply te...

Страница 14: ...ps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance to the manufacturer s instructions and in the direction of the polish lines Precautions Avoid prolonged contact with chlorides bleaches salts bromides sanitizing agents thiocyanates pesticides photography chemicals and some foods and iodides on...

Страница 15: ... continues replace the fitting or contact your Bradley representative for assistance Manual Release Button Sealing Ring Air Valve Tubing Locking Slope Gripping Ridge Tube Stop Water Tube Connector Air Valve Filter Cap Air Tube Connector Troubleshooting Stop Valve Problem Cause Solution Water just dribbles or does not flow from sprayhead Water supply malfunctioning 1 Close the stops and check the v...

Страница 16: ...ly 1 Check all tubing and fittings for proper assembly 2 Tighten cap and nut on 1 8 tubing Pushbutton does not work properly Air volume may not be sufficient to operate valve Check for leaks and lubricate U cup 1 Check all fittings for air leaks 2 Disassemble pushbutton and lubricate U cup seal see pushbutton assembly diagram Water is dripping from the streamformers Debris has accumulated on valve...

Страница 17: ...ion and the adjacent station should turn on If the adjacent station turns on and cycles normally replace the cartridge on the problem valve If the adjacent valve fails to turn on inspect the wires from the sensor cable and do the following make sure there are no breaks and that the fully insulated disconnect terminals are firmly crimped in place turn off the electrical and water supplies reconnect...

Отзывы: