Bradley Aerada 1000 Series Скачать руководство пользователя страница 1

IMPORTANT!

Read this entire installation manual to ensure proper installation. When 
fi nished with the installation, fi le this manual with the owner or maintenance 
department. Compliance and conformity to local codes and ordinances is 
the responsibility of the installer.

Separate parts from packaging and make sure all parts are accounted for 
before discarding packaging material. If any parts are missing, do not begin 
installation until you obtain the missing parts.

Make sure that all water supply lines have been fl ushed and then completely 
turned off before beginning installation. Do not use pipe dope. Debris in 
supply lines can cause valves to malfunction.

Product warranties may be found under “Products” on our web site at 
www.bradleycorp.com.

Installation

THIS
SIDE

UP

Packing List




P.O. Box 309, Menomonee Falls, WI 53052-0309
Phone: 1-800-BRADLEY    Fax: 262-253-4161
www.bradleycorp.com

Installation

215-1628 Rev. A; EN 08-201
© 2008 Bradley Corporation
Page 1 of 14 

5/21/08

Aerada 1000 Series Faucet

S53-326 AC Gooseneck
S53-327 DC Gooseneck

Aerada 1100 Series Faucet

S53-328 AC High Arc Infrared
S53-329 DC High Arc Infrared

Table of Contents

Supplies Required . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Manual Settings  . . . . . . . . . . . . . . . . . . . . . . . . 6
Adjustments. . . . . . . . . . . . . . . . . . . . . . . . . . .9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . 10
Care and Maintenance  . . . . . . . . . . . . . . . . . 12
Multi-Faucet Transformer Wiring . . . . . . . . . 14

Aerada 1000

Aerada 1100

Содержание Aerada 1000 Series

Страница 1: ...fore beginning installation Do not use pipe dope Debris in supply lines can cause valves to malfunction Product warranties may be found under Products on our web site at www bradleycorp com Installation TH IS SIDE UP Packing List P O Box 309 Menomonee Falls WI 53052 0309 Phone 1 800 BRADLEY Fax 262 253 4161 www bradleycorp com Installation 215 1628 Rev A EN 08 201 2008 Bradley Corporation Page 1 o...

Страница 2: ...with during handling of this product Make sure there is enough space and lighting available during installation and service Do not modify or convert this Faucet any modifications will void warranties Installation may be performed at different times of construction by different individuals For this reason these instructions should be left on site with the facility or maintenance manager Pressurized...

Страница 3: ...943 Filter only 269 1948 10 Deck Mounting Hardware Kit 269 1949 11 Electronics Module Kit 269 1941 12 Solenoid Valve 269 1940 COMPONENT PARTS Aerada 1000 Series Gooseneck Components Bradley Part Nos 1 Spout 269 1958 2 Shut Off Screw Assembly 269 1944 3 Outlet Assembly Kit Spout 5 GPM 269 1947 4 Gooseneck Base without opening 269 1959 5 6 V Lithium Battery CR P2 261 010 6 AC Adaptor Kit 269 1942 7 ...

Страница 4: ...ive covering from sensor until starting up faucet operation Do not tighten locknut before step 4 is completed 1 Mount cover plate if required Plumber s putty is recommended to seal the cover plate to the sink Security pin must be located on the left side 2 Mount gasket and put faucet into sink 3 Mount bracket from underneath Place hoses through large opening and mounting rod through small opening ...

Страница 5: ...l items from sink 3 Remove protective covering from sensor 4 Wait for 15 seconds for the faucet to calibrate to its environment Result The faucet is now activated 15 sec Test Function 1 Hold hand in front of sensor Water flow starts WARNING Hot water may burn your skin Hold hand carefully under water and remove quickly 2 For faucets with external mixer turn mixer handle from cold to warm Water tem...

Страница 6: ...be saved Prerequisites Water supply valve is open Battery is full LED does not blink for DC faucets AC power is on for AC faucets 1 Remove shut off screw 2 Remove mixer handle only for faucets with external mixer 3 Remove housing vertically 4 Remove battery from battery holder 5 The following procedure a b c must be done three 3 times in a row a Re insert battery b LED lights up c Remove battery i...

Страница 7: ...Mode Setting the normal mode will allow the faucet to activate only when it senses a hand presence 1 Enable Manual Setting Mode See Enabling Manual Setting Mode section 2 Fully cover sensor with hand Water flow stops after 5 seconds Continue to hold on for one 1 additional water pulse 3 Remove hand Result Normal Mode is now activated C Setting Metering Mode 10 seconds Setting the metering mode wil...

Страница 8: ...additional water pulses 3 Remove hand Result Scrub Mode is now activated for 180 seconds F Sensor Range Adjustment The detection distance of the sensor can be adjusted between approximately 4 11 inches from the infrared window 1 Enable Manual Setting Mode See Enabling Manual Setting Mode section 2 Remove all items from the sink 2 Fully cover sensor with hand Water flow stops after 5 seconds Contin...

Страница 9: ...erating Modes Description A Cleaning Mode The faucet is inactive for 90 seconds B Normal Mode The faucet is activated if it senses a hand presence This is the default operating mode of the faucet C Metering Mode 10 s The faucet will shut off after 10 seconds regardless of hand presence detected D Scrub Mode 60 s The faucet will shut off 60 seconds after the detection of the last hand presence E Sc...

Страница 10: ...r Power adapter contacts are corroded AC faucets only Clean contacts Connecting cable is kinked or broken AC faucets only Replace defective parts See Replacement Parts No external power supply AC faucets only Check external power supply Provide power supply Shut off screw is missing or defective Replace shut off screw See Replacement Parts Solenoid valve inoperable Replace solenoid valve See Repla...

Страница 11: ... or scratched Clean window with smooth cloth Input line pressure fluctuates Install appropriate line pressure regulators Faucet is leaking water Connections between housing and braided hoses are loose Check O rings Replace O rings when damaged or missing Connection between braided hose and inlet supply are loose Check rubber washers Replace washers when damaged or missing Connection between valve ...

Страница 12: ...Setting mode See Manual Setting instructions When cleaning mode is activated the faucet will be inoperable for 90 seconds 1 Fully cover sensor with hand until water flow stops This takes approximately 5 seconds 2 Remove hand Result Cleaning Mode is now activated Replacing Battery A traditional lavatory faucet is shown as an example These instructions apply to all DC models Prerequisites Battery is...

Страница 13: ...d water white label Hot water no label Result The filter is now cleaned or replaced Adjusting Hot Water Limiter External Mixer The proportion of hot water can be switched from approximately 85 to 95 or reverse depending upon inlet water pressures and temperatures The default setting is 85 WARNING Hot water may burn your skin Hold hand carefully under water and remove quickly 1 Remove mixer handle ...

Страница 14: ...lace aerator then reinstall 3 Install shut off screw Result The aerator is now cleaned or replaced Multi Faucet Transformer Installaion 232 009 1 8 faucets Transformer can be used to connect up to 8 faucets All units must be connected in parallel AC CONNECTOR FROM FAUCET BANK INSTALLATION ADAPTER WIRE BANK INSTALLATION ADAPTER WIRE INCL W AC FAUCET ADDITIONAL WIRING IF NEEDED TO BE SUPPLIED BY CUS...

Отзывы: