Condensing PV Series
6
Power supply
Dedicated 115 VAC, 60 Hz, 15A.
Gas Supply Pipe Minimum 1/2” NPT (schedule 40 black iron pipe recommended).
Approved Gas
Type
Natural Gas or Propane, unit must match gas type supplied.
Gas Pressure
5.0” w.c. min. for Natural Gas, 11.0” w.c. min. for Propane, 14.0” w.c. maximum
(Natural Gas & Propane).
Venting System
Power vent through the wall or vertical through the roof.
Approved Vent
Materials
PVC, CPVC or ABS.
Minimum
Clearance for
Servicing
18” from top, 24” from front, 4” sides and rear.
Water Supply
Pressure
150 psi maximum allowable working pressure. Check local codes for supply
pressure.
Gas Control
ECO Limit
Residential 188°F (87°C), Commercial 199°F (93°C).
Residential
Temperature Set
Point Range
60°F (16°C) to 160°F (71°C) (approximate temperatures).
Commercial
Temperature Set
Point Range
80°F (27°C) to 180°F (82°C) (approximate temperatures).
Blower
Temperature
Switch
Normally closed, opens @ 155°F (68°C), auto reset @ approximately 135°F (57°C).
Pressure Switch
Normally open
Closes on vacuum increase @ -1.73” w.c.
Blower
115 VAC, 60 Hz, 3.3 amps, 3000 RPM @ 1.5” w.c.