KwickShot® Flow controlled models
LED Pattern
Status/Problem
Possible causes
Heater response
Possible solutions
Solid light
Heating
N/A
N/A
N/A
One flash every four
seconds
Idle
N/A
- unit waits for flow
N/A
Two flashes once,
three second pause
Low heat
- outlet temperature below 90°F/32°C
for 5 seconds of flow
- element failure
- ECO tripped/malfunctioning
- relay/contactor malfunctioning
- control board failure
- inlet water supply out of spec
- unit keeps running,
LED flashes a warning
pattern
- reduce flow through
unit
Two flashes twice,
three second pause
Outlet thermistor failure
- outlet thermistor interrupted or
disconnected
- unit keeps running,
LED flashes a warning
pattern
- inspect
connections/wiring of
outlet thermistor
Two flashes three
times, three second
pause
Over-temperature
Warning
- outlet temperature exceeds
110°F/38°C
- unit keeps running,
LED flashes a warning
pattern
-increase flow through
unit. If this
temperature is desired
no action is required
Three flashes once,
three second pause
Over-temperature
Protection
- outlet temperature exceeds
150°F/65
°
C
- unit stops heating until
outlet temperature falls
below preset minimum
- increase flow through
unit to decrease the
overall temperature
rise
Three flashes twice,
three second pause
Freeze warning
- inlet temperature is too low (below
35
°
F/2°C)
- heating disabled
- increase temperature
of inlet water to meet
product specifications