SECTION 6: KwickShot® THERMOSTATIC MODEL OPERATION
Factory temperature setpoints/maximum adjustable range:
KwickShot®
Thermostatic
models
Default
Setpoint
(°F)
Minimum
Setpoint
(°F)
Maximum
Setpoint
(°F)
Base Model
<4kW
105
70
140
>4kW
120
ML (Multi Lavatory)
110
70
110
CHANGING SETPOINT TEMPERATURE
To INCREASE temperature, tap the “+” button repeatedly, or hold the “+” down to INCREASE the temperature quickly. To
DECREASE temperature, tap the “–” button repeatedly, or hold the “–” down to DECREASE the temperature quickly.
ADVANCED FUNCTIONS
With the
display showing the current setpoint temperature, press BOTH “+” AND “–” buttons simultaneously for 3 seconds.
Screen Info
Title
Units
Description
Flow Rate
FLO
GPM or LPM
Current water flow rate through unit
Inlet temperature
IN
°F or °C
Cold water temperature
Outlet temperature
OUT
°F or °C
Hot water temperature
Power Factor
PF
%
How hard the heater is working
Software Revision
SR
-
For Technical Support assistance
Hold “-” to display the current screen title.
Press “+” to advance to the next screen.
Holding both “+” and “–” at any time for 3 seconds returns the display to the temperature set point, or just let the heater
return to set point display on its own after a period of time.
ERROR CODES & UNITS
From Advanced Menu, press and hold the “+” and “–” buttons for 10 seconds.
Screen Info
Title
Description
Current Error(s)
CE
Any errors currently present (F0 displays if no errors are present)
Past Errors
PE
Previous 5 errors and faults
Units
UN
Choose between °F/GPM and °C/LPM
Eco Mode*
ECO
Toggle non-silent operation
* Thermostatic models only
Pressing “-” at any time will display screen title (CE, PE1-5, UN, ECO).
Press the “+” button for 1 second to cycle through the following screens:
To return to setpoint hold “+” and “–” for 10 seconds, or just let the heater return to setpoint display or display turn-off on
its own after a period of time.