Before removing the front cover, make sure the unit is mounted correctly with the 
water fittings at the bottom.

  

 

 

Water in

 

Water out

 

Serial number 

 
When correctly mounted, this “ Series Two” water 
heating unit should look like the diagram to the 
left.  ANY other mounting configuration will 
prevent the unit from operating properly. 

UP 

 

Remove the front cover and observe the 
indicator light on the circuit board of each 
module.

 

 
With the power switched 

“ON”

 to the unit, run 

water through the unit by opening several faucets 
supplied by the unit.  If any indicator lights 
illuminate, note their position and if the 
illumination is steady or pulsing. 

 

If there are no indicator lights illuminated, then: 

 

If there are no indicator lights illuminated, measure the flow rate of water going through the unit. 
 
The “

activating flow rate

” varies with each model. You must determine which “Series Two” model 

you have. Look at the rating label, find the 

order ref. number

 and then (From the data) cross 

reference the required flow rate to activate the unit.

  

 
Measuring Flow Rate: 
1)  “EFT” requires at least 0.9 gallons per minute to switch on.

   

 

Fill a 1-gallon “milk” container and, using only water from the hot water outlet, record the time 
(In seconds) required to fill. To calculate the flow rate, divide the number of gallons the 
container holds (in this case one gallon) by the time required to fill. 
 
e.g. If it takes 87 seconds to fill the container then the flow rate would be  
Flow Rate (gpm)=v/t x 60 = 1 gal./87 seconds x 60 seconds/1 minute=.69 GPM 
 
If there is insufficient water flow to activate the unit, then you must provide more water to the 
system by 

opening the valves fully.  

If there is sufficient water flow and still no indicator lights, then proceed to the next step.

 

 

 

 

Содержание EFT-15000-4-D-10

Страница 1: ...0 277V EFT 20000 5 D 10 277V All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exist after reading and carrying out the instructions in this manual contact Technical Service at the toll free number below for assistance PHONE TOLL FREE 1 800 334 3393 238 43143 00 Rev 5 02 ...

Страница 2: ...r going through the unit The activating flow rate varies with each model You must determine which Series Two model you have Look at the rating label find the order ref number and then From the data cross reference the required flow rate to activate the unit Measuring Flow Rate 1 EFT requires at least 0 9 gallons per minute to switch on Fill a 1 gallon milk container and using only water from the h...

Страница 3: ...le Rx1 scale or the Rx10 scale then the element is good if it is much greater e g 10 000 Ohms or if you get a reading on the Rx1k you will need to replace the element To do this contact Technical Service at 1 800 334 3393 for replacement elements Please write down the resistance value before contacting Technical Service this will be very useful to us Also have the order ref number and serial numbe...

Страница 4: ...the unit This board may have been incorrectly positioned if serviced previously The correct mounting holes for the PCB on all ES EFC or EFT models Board mounted in correct position Inlet filter Note The upper mounting position is applicable to all modules regardless of their type Inspect the inlet filter Inspect the inlet filter See diagram above for location Make sure the inlet filter screen is f...

Страница 5: ...tatic modules only If the indicator light on the circuit board flashes one time very quickly when the water is switched on then Warning Turn off all power to the water heating unit 1 Turn OFF the power to this unit and all other units that may feed hot water to this unit including the right hand side module and any other preheating units 2 Be sure that this module is fed with cold water only durin...

Страница 6: ... water flowing and there is no heating of the water it is highly likely that the heating element has been damaged If the above situation occurs contact Technical Service for replacement elements IF HAVING CARRIED OUT ALL THE TESTS LISTED ABOVE AND THE WATER HEATING UNIT IS STILL NOT FUNCTIONING PLEASE CONTACT TECHNICAL SERVICE AT 1 800 334 3393 PLEASE HAVE THE FOLLOWING INFORMATION AVAILABLE 1 ORD...