Bradford White EFT-15000-4-D-10 Скачать руководство пользователя страница 5

 

“Series Two” water heaters are comprised of two individual heating modules. For the purpose of 
troubleshooting, each of these two modules will be considered as a separate unit.  Neither having 
any effect on the performance of the other. These modules fall in to 

one of

 

two categories

 

1) Thermostatically controlled modules 

 

2) Flow controlled modules. (Non-thermostatic)

 

 

 
 
Model Types / Order Ref Number: 
 

Look at the order ref. number on the label located on the front cover of the unit. In the top 
left hand box find the “Order Ref.” Find the order reference number on the list below to 
confirm the type of heating modules you have. 
 

Heater Model Number 

                                         Module Types and Qty. 

Order Ref Number: & UL Rating Label 

 

Thermostatic          Flow Controlled 

 
EFT-15000-4-D-10                                                         1                              1 
EFT-19000-4-D-10                                                           1                              1 
EFT-16000-5-D-10                                                           1                              1    
EFT-20000-5-D-10                                                           1                              1

 

 

 

 

For “Thermostatic” modules only 

 

If the indicator light on the circuit board flashes one time very quickly when 
the water is switched on then:

 

 

Warning 

Turn off all power to the water heating unit.

 

 
 

1) Turn 

“OFF”

 the power to this unit and all other units that may feed hot water to this unit, 

including the right hand side module and any other preheating units. 

 
2) Be sure that this module is fed with 

cold water only during this test

. This unit must not be fed 

with pre-heated water when performing this test. 

 
3) There are six thin leads connected to the printed circuit board. Disconnect the 

third wire

 from 

the left, from the top of the PCB (As indicated below) and tape off the end with insulating tape.

  

 

4) 

Run water from hot water faucet for 30 seconds and then switch power 

“ON”

 to the unit once 

more.

  

 

With the water flowing: 

If the light illuminates steadily, contact Technical Service and request a replacement printed circuit 
board (Part #EX100). If the light still does not illuminate contact Technical Service and consult 
with a technician. 

Содержание EFT-15000-4-D-10

Страница 1: ...0 277V EFT 20000 5 D 10 277V All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exist after reading and carrying out the instructions in this manual contact Technical Service at the toll free number below for assistance PHONE TOLL FREE 1 800 334 3393 238 43143 00 Rev 5 02 ...

Страница 2: ...r going through the unit The activating flow rate varies with each model You must determine which Series Two model you have Look at the rating label find the order ref number and then From the data cross reference the required flow rate to activate the unit Measuring Flow Rate 1 EFT requires at least 0 9 gallons per minute to switch on Fill a 1 gallon milk container and using only water from the h...

Страница 3: ...le Rx1 scale or the Rx10 scale then the element is good if it is much greater e g 10 000 Ohms or if you get a reading on the Rx1k you will need to replace the element To do this contact Technical Service at 1 800 334 3393 for replacement elements Please write down the resistance value before contacting Technical Service this will be very useful to us Also have the order ref number and serial numbe...

Страница 4: ...the unit This board may have been incorrectly positioned if serviced previously The correct mounting holes for the PCB on all ES EFC or EFT models Board mounted in correct position Inlet filter Note The upper mounting position is applicable to all modules regardless of their type Inspect the inlet filter Inspect the inlet filter See diagram above for location Make sure the inlet filter screen is f...

Страница 5: ...tatic modules only If the indicator light on the circuit board flashes one time very quickly when the water is switched on then Warning Turn off all power to the water heating unit 1 Turn OFF the power to this unit and all other units that may feed hot water to this unit including the right hand side module and any other preheating units 2 Be sure that this module is fed with cold water only durin...

Страница 6: ... water flowing and there is no heating of the water it is highly likely that the heating element has been damaged If the above situation occurs contact Technical Service for replacement elements IF HAVING CARRIED OUT ALL THE TESTS LISTED ABOVE AND THE WATER HEATING UNIT IS STILL NOT FUNCTIONING PLEASE CONTACT TECHNICAL SERVICE AT 1 800 334 3393 PLEASE HAVE THE FOLLOWING INFORMATION AVAILABLE 1 ORD...

Отзывы: