Locating The Water Heater continued-
Water heater corrosion and component failure can be caused by the heating
and breakdown of airborne chemical vapors. Examples of some typical
compounds that are potentially corrosive are: spray can propellants, cleaning
solvents, refrigerator and air conditioning refrigerants, swimming pool
chemicals, calcium or sodium chloride, waxes and process chemicals.
These materials are corrosive at very low concentration levels with little or no
odor to reveal their presence.
NOTE: THE MANUFACTURER OF THIS WATER HEATER WILL NOT
ACCEPT RESPONSIBILTY FOR DAMAGE TO THE WATER HEATER
CAUSED BY EXPOSURE TO CORROSIVE VAPORS. DO NOT OPERATE
THE WATER HEATER IF EXPOSURE HAS OR WILL OCCUR. DO NOT
STORE ANY POTENTIALLY CORROSIVE COMPOUNDS IN THE
VICINITY OF THE WATER HEATER.
This water heater must be located in an area where leakage of the tank or
water line connections and the combination temperature and pressure relief
valve will not result in damage to the area adjacent to the water heater or to
lower floors of the structure. When such locations cannot be avoided, a
suitable drain pan must be installed under the water heater. The drain pan
must have a minimum length and width of at least 4 in. (10.2 cm) greater
than the diameter of the water heater. The drain pan, as described above,
can be purchased from your plumbing professional. The drain pan must be
piped to an adequate drain. The piping must be pitched for proper drainage.
This water heater MUST be installed indoors out of the wind and
weather.
Note: For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an earthquake.
See instructions for correct installation procedures. Instructions may
be obtained from the DSA Headquarters Office, 1102 Q Street, Suite
5100, Sacramento, CA 95811.