background image

 

B

RADFORD

 W

HITE

 C

ORP.

Page 48

105  Switch, Low water cutoff, Manual Reset 

RE2075100 

RE2075100 

RE2075100 

RE2075100 

HEAT EXCHANGER / WATER PATH – 

See Figures 34 and 35

110 

Header 

cover 

12A4200 16A4200 20A4200 24A4200

111 

Water 

barrier 

assembly 

12B4100 16B4100 20B4100 24B4100

112  Gasket, heat exchanger cover 

S2011900 

S2102500 

S2102600 

S2012300

113  Hardware kit, heat exchanger cover 

R2013100 

R2023700 

R2023800 

R2008300

114 

Gauge, 

temperature/pressure 

RA0079000 RA0079000 RA0079000 RA0079000

115  Pressure relief valve, RHCH boiler 

A0063600 

A0063600 

A0002700 

A0002700

115  Pressure relief valve, RHCV boiler 

A0001200 

A0001200 

A0000400 

A0000400

116  Immersion well, high limit 

RE2058300 

RE2058300 

RE2058300 

RE2058300

117  Immersion well, temperature control 

RE2074000 

RE2074000 

RE2074000 

RE2074000

118  Tube cleaning kit (not shown) 

R2000700 

R2000700 

R2000700 

R2000700

119  Flow switch (with paddle) 

R2008400 

R2008400 

R2008400 

R2008400

120  Temperature Control, 100° to 200° F, SPDT 

E2315000 

E2315000 

E2315000 

E2315000

121  Temperature Sensor, 1/8" NPT 

E2314300 

E2314300 

E2314300 

E2314300

122  Low water cutoff Probe Cover/Plate 

R2027000 

R2027000 

R2027000 

R2027000

123  Pipe Assembly (condenser to valve) 

P2040501 

P2040501 

P2040501 

P2040501

124  Pipe Assembly (outlet to pump) 

P2040505 

P2040508 

P2040509 

P2040503

125  Pipe Assembly (valve to pump) 

P2040506 

P2040506 

P2040510 

P2040502

126  Pipe Assembly (coil to inlet) 

P2040507 

P2040507 

P2040504 

P2040504

127 

Valve 

Control 

Arm 

 

24A9200 24A9200 24A9200 24A9200

128 

Valve 

Connection 

Rod 

12A9206 12A9206 20A9206 24A9206

129 

Control 

Arm 

Hardware 

Kit 

R2027100 R2027100 R2027100 R2027100

130 

Actuator, 

Valve, 

Electronic 

A2110000 A2110000 A2110000 A2110000

131 

Bracket, 

Support, 

Actuator 

24A9214 24A9214 24A9214 24A9214

132 

Bracket, 

Mounting, 

Actuator/Control 

12A9207 16A9207 20A9207 24A9207

133 

Pipe 

Gasket 

Kit 

R2027200 R2027200 R2027200 R2027200

134 

Valve, 

Butterfly, 

2-Way 

A2109900 A2109900 A2109900 A2109900

135  Pipe Hardware  Kit 

R2027300 

R2027300 

R2027300 

R2027300

136 

Bracket, 

Pipe 

Support 

24A1003 24A1003 24A1003 24A1003

137  Nipple, Close, 2" NPT 

P2011700 

P2011700 

P2011700 

P2011700

138  Elbow, Bronze, 2-1/2" Class 150 

P2048400 

P2048400 

P2048400 

P2048400

139  Soft Water Pump Assembly 

A2112100 

A2111500 

A2111500 

A2111400

 

Normal 

Water 

Pump 

Assembly 

A2111500 A2111400 A2111400 A2111200

 

Hard Water Pump Assembly 

A2111400 

A2111200 

A2111200 

-

JACKET – 

See Figure 36

140  Panel, upper front access 

24B3200 

24B3200 

24B3200 

24B3200

141  Panel, lower front access 

24B3300 

24B3300 

24B3300 

24B3300

142 

Panel, 

waterway 

access 

12A3014 12A3014 20A3014 24B3014

143 

Panel, 

waterway 

cover 

24B3012 24B3012 24B3012 24B3012

144 

Panel, 

pump 

cover 

24B3016 24B3016 24B3016 24B3016

145 

Panel, 

PRV 

access 

24B3019 24B3019 24B3019 24B3019

146 

Panel, 

rear 

access 

24A3006 24A3006 24A3006 24A3006

147 

Panel, 

front 

left 

24B3001 24B3001 24B3001 24B3001

148 

Panel, 

front 

right 

24B3002 24B3002 24B3002 24B3002

149 

Panel, 

rear 

left 

24A3003 24A3003 24A3003 24A3003

150 

Panel, 

rear 

right 

24A3004 24A3004 24A3004 24A3004

151 

Panel, 

common 

access 

24B3005 24B3005 24B3005 24B3005

152 

Panel, 

top 

24B3007 24B3007 24B3007 24B3007

153 

Panel, 

support 

24B3008 24B3008 24B3008 24B3008

154  Panel, flue vent access 

12B3010 

12B3010 

20B3010 

24B3010

155  Panel, ducted air cover 

24B3011 

24B3011 

24B3011 

24B3011

156 

Jacket 

trim 

kit 

R2009600 R2009600 R2009600 R2009600

157 

Hardware 

kit, 

jacket 

R2009700 R2009700 R2009700 R2009700

158  Window, control / display 

A2108200 

A2108200 

A2108200 

A2108200

159 

Window 

guide 

24B3102 24B3102 24B3102 24B3102

160 

Window 

latch 

R2010000 R2010000 R2010000 R2010000

161  Jacket retro-fit kit (standard) 

R2026400 

R2026500 

R2026600 

R2026700

162  Jacket retro-fit kit (mounted pump) 

R2026800 

R2026900 

R2027000 

R2027100

 

 

1200 1600 2000 2400

Содержание BRHHH

Страница 1: ...tallation and maintenance Improper installation and or operation could create carbon monoxide gas in ue gases which could cause serious injury property damage or death Improper installation and or ope...

Страница 2: ...BRADFORD WHITE CORP Page 2...

Страница 3: ...e Water Heater Temperature Control 24 5 4 2 Internal Water Heater Temperature Control 25 5 5 Temperature Control Features 25 5 5 1 Temperature Setpoint 25 5 5 2 Differential Setting 25 5 5 3 Offset 26...

Страница 4: ...Wiring Diagram Size 1200 Standard and Codes A and F 30 Figure 18 Wiring Diagram Sizes 1600 2000 and 2400 Standard and Codes A and F 31 List of Tables Table 4 Required Combustion Air Piping Material 9...

Страница 5: ...actory or local factory representative with any problems or questions regarding this equipment Experience has shown that most operating problems are caused by improper installation The Brute Magnum ap...

Страница 6: ...or alcoves Brute Magnum Boilers or Water Heaters must never be installed on carpeting The location for the appliance should be chosen with regard to the vent pipe lengths and external plumbing The un...

Страница 7: ...for Correct Vent Distance From Outside Wall or Roof Termination The forced draft combustion air blower in the appliance has sufficient power to vent properly when the guidelines in Table 2 are followe...

Страница 8: ...total input rating of all equipment in the enclosure When communicating to the outdoors through horizontal ducts each opening shall have a minimum free area of not less than 1square inch per 2000 Btu...

Страница 9: ...e Magnum units unless the vent system meets this requirement Brute Magnum units are never permitted to share a vent with Category I appliances A condensate drain is built into the Brute Magnum A press...

Страница 10: ...ide of opening 36 inches 91 cm any other appliance 1 foot 30 cm above opening K Clearance to a mechanical air supply inlet 3 feet 91 cm above if within 10 feet 3 m 6 feet 1 83 m horizontally Vent term...

Страница 11: ...plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling building or structure served by th...

Страница 12: ...hlorine compounds etc 2 Locate the terminal so that it will not be subject to damage by accident or vandalism It must be at least 7 feet 2 1m above a public walkway 3 Locate the combustion air termina...

Страница 13: ...lines in the National Fuel Gas Code ANSI Z223 1 NFPA 54 and or CSA B149 1 Installation Codes Section 3 GAS SUPPLY AND PIPING 3 1 Gas Supply and Piping Gas piping should be supported by suitable hanger...

Страница 14: ...k and a hydronic flow check in the system supply loop Minimum fill pressure must be 12psig 82 7kPa Install shutoff valves where required by code Suggested piping diagrams are shown in Figures 4 5 and...

Страница 15: ...atures are expected to fall below 15 F inside the boiler cabinet the actuating gas valve must be equipped with a gas valve heater part number R2010100 Note that some gas trains such as the IRI option...

Страница 16: ...ness of the water The water flow is kept high enough to prevent scaling but low enough to prevent tube erosion For extremely soft or hard water cupro nickel tubes are available Contact a Bradford Whit...

Страница 17: ...the water at the inlet of the copper heat exchanger is 140 F 60 C or higher the water will be allowed to flow through the copper heat exchanger and directly to the outlet of the Brute Magnum and ther...

Страница 18: ...t shall not be introduced into the potable Figure 6 Hydronic Piping One Boiler Multi Temperature System water used for space heating This water heater when used to supply potable water shall not be co...

Страница 19: ...nd the heater is not able to fire and or the water is not able to circulate there is a risk of freezing in the heater or in the pipes in the system When water freezes it expands This can result in bur...

Страница 20: ...BRADFORD WHITE CORP Page 20 Figure 8 Water Heater Piping One Heater One Tank...

Страница 21: ...Brute Magnum Page 21 Figure 9 Water Heater Piping Multiple Heaters One Tank...

Страница 22: ...BRADFORD WHITE CORP Page 22 Figure 10 Water Heater Piping One Heater Multiple Tanks...

Страница 23: ...Brute Magnum Page 23 Figure 11 Water Heater Piping Multiple Heaters Multiple Tanks...

Страница 24: ...t are wired at the factory to the pump time delay system It is necessary to wire the pump to a separate 115V or 230V single phase circuit per the wiring diagrams in Figures 17 through 20 5 3 Temperatu...

Страница 25: ...the appliance 5 5 Temperature Control Features The Brute Magnum temperature control is versatile and will allow the user to better match the modulating control to the application Settings that can be...

Страница 26: ...will modulate This will tell the controller how fast to respond to a change in temperature A small throttling range keeps the unit in high fire more and quickens the response of the system A larger t...

Страница 27: ...gnum installations Medium Switch 3 to ON position and all others to OFF The integration constant is set to Medium at the factory and in most cases will not need to be 25 and 100 of full fire between 4...

Страница 28: ...The control will then display Add for the second menu If no more buttons are pushed the control will automatically return to the temperature display mode changed This setting will be the best suited t...

Страница 29: ...external control terminal strip located to the right of and behind the front panel The terminal strip is labeled 0 10VDC and 0 10VDC to indicate which terminal received the hot signal and which termin...

Страница 30: ...BRADFORD WHITE CORP Page 30 Figure 17 Wiring Diagram Size 1200 Standard and Codes A and F...

Страница 31: ...Brute Magnum Page 31 Figure 18 Wiring Diagram Sizes 1600 2000 and 2400 Standard and Codes A and F...

Страница 32: ...BRADFORD WHITE CORP Page 32 Figure 19 Wiring Diagram Size 1200 Code B...

Страница 33: ...Brute Magnum Page 33 Figure 20 Wiring Diagram Sizes 1600 2000 and 2400 Code B...

Страница 34: ...BRADFORD WHITE CORP Page 34 Figure 21 Wiring Schematic Model 1200 Standard and Codes A and F Figure 22 Wiring Schematic Models 1600 2000 and 2400 Standard and Codes A and F...

Страница 35: ...Brute Magnum Page 35 Figure 23 Wiring Schematic Model 1200 Code B Figure 24 Wiring Schematic Models 1600 2000 and 2400 Code B...

Страница 36: ...ated above the boiler insures that water is at the highest point in the circulating loop then the system is ready for operation 14 Refer to local codes and the make up water valve manufacturer s instr...

Страница 37: ...ach the manometer pressure lines to the barbs Be sure all connections are gas tight 12 Switch on the appliance power switch located on the front of the unit 13 The Brute Magnum will enter the start se...

Страница 38: ...ignition Section 7 MAINTENANCE WARNING Disconnect all power to the appliance before attempting any service to the appliance Contact with electricity can result in severe injury or death 7 1 System Ma...

Страница 39: ...Brute Magnum Page 39 Figure 27 Gas Trains...

Страница 40: ...s the filter remove the unit s front panel Disengage latch on top of filter box and remove the filter box cover Inspect the air filter If there is debris on the air filter remove it from the filter bo...

Страница 41: ...display shut off the 120 volt power to the appliance Remove the cover from the control panel and remove the screws from the DIN rail clip to which the controls are mounted Pull the electrical connect...

Страница 42: ...d the 120 volt current remains on to the blower at all times If a blower change is required turn off the 120 volt power and gas supply to the unit Take the front panel the two side access panels and t...

Страница 43: ...body shut off 120V power and the gas shutoff valve Remove the right side and front panels Remove the valve actuator Unscrew the valve body from the gas train After the valve has been removed replace w...

Страница 44: ...ual reset button see Detail A in Figure 30 Control Panel 8 3 Delayed Ignition Possible Causes 8 3 1 High Lockup Pressure LP Appliances Occurs on Start up High lock up pressure is the most common cause...

Страница 45: ...Appliances operating with an improper air fuel ratio are very inefficient and consequently have very high gas consumption Because efficiency is high when the CO2 is high or O2 is low appliances opera...

Страница 46: ...AIR COMPONENTS See Figures 31 and 32 35 Gas train assembly standard Nat 12B6000 16B6000 20B6000 24B6000 35 Gas train assembly standard LP 12B6020 16B6020 20B6020 24B6020 35 Gas train assembly control...

Страница 47: ...ngle Trial E2311900 E2311900 E2311900 E2311900 76 Ignition control Three Trial Control packs F and G E2312000 E2312000 E2312000 R2022600 77 High limit manual reset RHCH boiler RE0015900 RE0015900 RE00...

Страница 48: ...Actuator Control 12A9207 16A9207 20A9207 24A9207 133 Pipe Gasket Kit R2027200 R2027200 R2027200 R2027200 134 Valve Butter y 2 Way A2109900 A2109900 A2109900 A2109900 135 Pipe Hardware Kit R2027300 R2...

Страница 49: ...Brute Magnum Page 49 Figure 30 Combustion Components...

Страница 50: ...BRADFORD WHITE CORP Page 50 Figure 31 Gas Train Combustion Air Components...

Страница 51: ...Brute Magnum Page 51 Figure 32 Gas Train Components...

Страница 52: ...BRADFORD WHITE CORP Page 52 Figure 33 Electrical Components...

Страница 53: ...Brute Magnum Page 53 Figure 34 Heat Exchanger Water Path Components...

Страница 54: ...BRADFORD WHITE CORP Page 54 Figure 35 Heat Exchanger Water Path Components...

Страница 55: ...Brute Magnum Page 55 Figure 36 Jacket Components...

Страница 56: ...vice Parts 800 538 2020 www BradfordWhite com Warranty Service 800 531 2111 Litho in U S A Bradford White 1102 Document 1246 Bradford White Company reserves the right to change specifications componen...

Отзывы: