Operating Instructions continued-
For the most energy efficient operation, adjust the aquastat for
the minimum water temperature necessary to meet domestic hot
water needs. Refer to Figure 8. Use a small flat screwdriver to
rotate the temperature dial through the hole directly below the
temperature indication window. The temperature setting is
aligned with the notch in this window.
IT IS NOT
NECESSARY TO REMOVE THE COVER TO ADJUST
THE TEMPERATURE SETTING. THE AQUASTAT
COVER SHOULD NEVER BE REMOVED WITHOUT
ELECTRICITY BEING FIRST DISCONNECTED.
Figure 8 - Aquastat Control
After the indirect-fired water heater completes a heat-up cycle,
check the water temperature at a faucet. Allow enough water to
flow to ensure that the water temperature reflects the tank
temperature. Adjust the water heater’s temperature setting as
necessary.
CAUTION
Before adjusting the aquastat, turn off all power supplied to the
indirect-fired water heater.