32
SECTION IX
TROUBLE SHOOTING GUIDE
PROBLEM CAUSE
SOLUTION
No hot water
at faucet
Boiler does not
operate
Refer to boiler installation
instructions
Check main service
switch
Check fused disconnect
Circulator does not
operate
Check power supply
Replace as necessary
Improper aquastat
setting or
calibration
Turn tank aquastat to
appropriate setting
Zone valve does
not open (if used)
Check power supply
Replace as necessary
Electrical problem
(relay, wiring, etc.)
Check fuse and replace
Check circuit breaker and
reset (if applicable)
Check power supply
Scale build-up
If boiler, circulator, and
tank are operating
satisfactorily, coil may
have scale coating. See
Section VIII:
Maintenance
Clogged cold water
filter or boiler
supply strainer (if
used)
Clean or replace filter or
strainer
Water at faucet
too hot
Improper system
plumbing
Compare plumbing to
Section V
Improper system
wiring
Compare wiring to
Section VI
Aquastat set too
high
Lower aquastat setting.
See Section VII