ENGLISH
ACQUIRING INSERTERS
The system cannot have inserters with the same address.
STEP 1: Activating inserters in the control unit
1.
Enter user code (if less than 6 characters confirm with
*
).
2.
Enter technical code to access technical menu.
3.
With
▲
▼
select
SYSTEM
and press
*
.
4.
With
▲
▼
select
EDIT SYSTEM
and press
*
.
5.
With
▲
▼
select
INSERTERS
.
6.
Use the number keys to select and activate inserter (# = activated , -
disactivated).
7.
Press
#
to return to previous menu.
STEP 2: Addressing the inserter
To assign an address to an inserter you need to:
1.
Staying inside the
SYSTEM
menu.
2.
With
▲
▼
select
ADDRESSING INSERTERS
and press
*
.
3.
The displays shows the inserter address which was not found on bus
and which needs to be addressed.
4.
Using a key (even one that you have not bought) approach the inserter
to which you wish to assign the address which appears on the display
and wait for the LED lights to flash slowly and for the buzzer to sound.
5.
The display will show
INSERTER 02 OK
. Press
*
to continue.
6.
If there are other inserters to address the procedure would restart
from the beginning.
7. Press
#
to output and return to the previous menus.
All of the inserters are made with address 1 and have no factory-activated inserter.
To address and acquire a new inserter from the control unit you need (example of added inserter 2):
08:23 16/05/10
ENTER CODE
123456
COMMAND WAITING
*=USER MENU
222222
SYSTEM 02
EDIT
SYSTEM
*
▼ ▲
▼ ▲
INSERTERS
#-----------------
▼ ▲
*
INSERTERS
##----------------
#
2
08:23 16/05/10
ENTER CODE
123456
COMMAND WAITING
*=USER MENU
222222
SYSTEM 02
ADDRESSING
INSERTERS
*
▼ ▲
▼ ▲
ON INSERTER 02
APPROACH KEY
▼ ▲
*
INSERTER OK
PRESS */OK
*
ACQUIRING THE EXPANISION MODULE IN THE CONTROL UNIT
The input expansion module has, at a local level, address number 1 and the control units have no factory-activated expansions.
To set up control unit for expansion you need: