11 PC – Contol unit connection
Once finished with the system components definition part (previous chapters) you can move on to programing the control unit from
either the keypad or the PC via direct or remote connection.
11.1 Locally Programming the RS-232
STEP 1: Opening the control unit
1.
Enter user code (if less than 6 characters confirm with
*
).
2.
Enter technical code to access technical menu.
3.
Open the control unit by loosening the apposite screws.
STEP 2: Placing the control unit in maintenance
To prevent alarms from being raised due to control unit tamper or due to
possible programming errors, we suggest placing the control unit into
maintenance mode.
1.
Place the control unit into maintenance mode
O
N
1
by raising
microswitch 1.
STEP 3: Connecting the to PC the control unit
1.
Install the control unit programming software onto your PC.
2.
Connect the control unit to the PC via a RS-232 standard cable
(direct male-female) or via a USB-RS232 cable.
STEP 4: PC setting (to do only once)
1.
Set the control unit access password on the PC (the same as the
technical 2222222 password which is already factory-set).
2.
Set the serial communications COM.
STEP 5: Control unit setting (to do only once)
There are two ways to program the control unit:
• With control unit shut down.
• With control unit shut down after entering user code.
To set one of the two modes you need to:
1.
Enter user code (if less than 6 characters confirm with
*
).
2.
Enter technical code to access technical menu.
3. With
▲
▼
select
CODES
and press
*
.
4.
With
▲
▼
select
INSTALLER’S TECHNICAL CODE
and press
*
.
5.
With
▲
▼
select
PROGRAM. FROM PC
.
6.
With
+
and
–
edit the parameter:
•
WITH CONTROL UNIT OFF
, direct programming without
entering user code with control unit off.
•
AFTER USER CODE
, programming only after entering
user code and with control unit shut down.
7. Press
#
to output and return to the previous menus.
08:23 16/05/10
ENTER CODE
123456
COMMAND WAITING
*=USER MENU
222222
08:23 16/05/10
ENTER CODE
123456
COMMAND WAITING
*=USER MENU
222222
CODES 16
INSTALLER’S
TECHNICAL CODE
*
▼ ▲
▼ ▲
PROGRAM. FROM PC
WITH CENTR. OFF
*
▼ ▲