B OUT
bus output towards recei-
vers or other entry panels
Terminal block M2
3
video signal
4
video signal earth
Connector functions
5-pin CN1 connector:
used for con-
nection to entry panel HEP/306 or
HEP/312D.
3-pin CN3 connector:
used for con-
nection to buttons KHPS or KHPD.
1-red:
to button n° 2.
2-orange:
to button n° 3.
3-yellow:
to button n° 4.
WARNING. In installations with a num-
ber of entry panels, call buttons must be
arranged in the same order on each.
Connector CN4:
comes ready con-
nected.
1-black:
to button no. 1.
2-brown:
to button no. 1.
3-green:
to LEDs lighting the buttons.
4-yellow:
to LEDs lighting the buttons.
2-pin CN5 connector:
used for con-
nection to KHSO luminous warning kit.
WARNING. Wires belonging to
cables that are not used must be
insulated.
Function of jumpers SW1 and SW2
(fig. 5)
SW1:
automatic programming of
number of entry panels (default set-
ting 1).
SW2:
programming of receivers.
Programming of number of entry
panels
(only required where there is
more than one entry panel)
1 -
Start with the last entry panel con-
nected in series to the bus (usually
the one with terminals
B IN
not con-
nected).
2 -
Remove jumper SW1.
3 -
Wait for the note confirming the
operation (approximately 3÷15 s).
The number of confirmation signals
also indicates the number of present
and programmed entry panels (1
signal for the main entry panel and 1
signal for each secondary entry panel).
4 -
Refit jumper SW1.
3
5
21
8
11
12
14
7
Programming receivers
1 -
Remove jumper SW2 from any
entry panel.
2 -
Lift the handset of the receiver to
be programmed (for telephone sets,
see the instructions featured in inter-
face IT/300).
3 -
Press the door-lock release and
auxiliary 2 buttons at the same time
for at least 1 s (when audio towards
the entry panel is enabled, the ope-
ration is confirmed).
4 -
On the entry panel, press the call
button the receiver is to be associa-
ted with.
5 -
Replace the handset.
6 -
Repeat the operation from point 2
on for all remaining receivers.
7 -
Refit jumper SW2 to exit program-
ming.
WARNING. The programming proce-
dure for the VSE/300 selector, where
fitted, must only be performed once
you have programmed which calls
from the entry panels are to be asso-
ciated with which receivers.
In installations with XA/300LR we
recommend you gather up the recei-
ver’s ID (SN) codes, applied on the
outside of the housing, and enter
them in the tables that come with
the XA/300LR, MPP/300LR and
IPC/300LR.
NOTE. Once the power supplier
has been programmed using a
PCS/300 or MPP/300LR unit, it will
no longer be possible to gain
access to the entry panel standard
programming.
To restore default conditions, plea-
se refer to the related chapter.
Return to default conditions from
entry panel
1 -
Remove the SW1 jumper.
2 -
Close the earthed door open con-
tact.
A sound signal confirms that the ope-
ration has occurred.
3 -
Replace the SW1 jumper.
Technical features
• Power supply:
14÷18 V DC.
• Current demand:
- on stand-by with 14 V DC max. 120
mA;
- operating with 14 V DC max. 240
mA;
- with door-lock release activated,
add 500 mA;
- for each HEP/306-HEP/312D, add
35 mA;
- for each XDV/304A connected,
add 40 mA;
- for 64 receivers, add 64 mA.
• Secrecy of speech/privacy of video
signal.
• Door-lock release command: pulse-
type for solenoid lock at 12 V 1 A.
• Installation activation time: 60 s.
• Call duration time: 30 s.
• Timed solenoid door-lock release:
adjustable in the range 1 to 15 s.
• Bus output: power supply at 15 V
DC for booster and receivers video
driver balanced type (Z = 100
Ω
).
• Aux 1 command output: 3.5 V DC
at 1mA (available only with entry
panel enabled, activation time
same as timed solenoid door-lock
release).
• Aux 2 command output: 3.5 V DC at
1 mA (always available in all entry
panels, activation time same as
timed solenoid door-lock release).
• Entry panel activation output: 3.5 V
DC at 1 mA (enabled for entire
duration of conversation).
• Working temperature range: -15 °C
to +50 °C.
Installation instructions
The embedding box must be fitted
flush with the wall at an appropriate
height.
Fit the spacer into embedding boxes
to avoid deformation (fig. 1).
WARNING. Connecting cables must
be fed through one of the knockout
cable entry points, located at the bot-
tom of the embedding box (A in fig. 1).
Using the Allenkey s 2.5 supplied,
unscrew the lock screw and remove
the front plate from the chassis (fig.
2).
Remove the two plugs protecting the
threaded holes in the embedding box
and secure the chassis using the two
screws supplied (fig. 3).
In order to fit additional buttons, fol-
low the instructions supplied with
each.
Perform the wiring. The name card
can be removed and filled in with the
relevant information by removing the
card clip followed by the actual card
itself (fig. 6).
NOTE.
Personalized name cards can
be used up to a maximum of 2 mm
thick.
In order to fit the front plate, first
insert the upper part in the top moul-
ding and then, using a Allenkey s 2.5,
tighten the lock screw (fig. 7).
DISPOSAL
Do not litter the environment with
packing material: make sure it is dis-
posed of according to the regulations
in force in the country where the
product is used.
When the equipment reaches the end
of its life cycle, take measures to
ensure it is not discarded in the envi-
ronment.
The equipment must be disposed of
in compliance with the regulations in
force, recycling its component parts
wherever possible.
Components that qualify as recy-
clable waste feature the relevant
symbol and the material’s abbrevia-
tion.
D
INSTALLATIONS-
ANLEITUNG
AUSSENSTATION FÜR
VIDEOSPRECHANLAGEN HET/301
Die Außenstation für Videosprech-
anlagen mit einer Taste ermöglicht
die komplette Anlagensteuerung. Für
die Anlagen geeignet, die den
Einbau einer von der Außenstation
getrennten Kamera vorsehen.
Durch die Kombination mit den
Ruftastentableaus HEP/306-HEP/312D
können Anlagen mit bis zu maximal 64
Stromabnehmern geschaffen werden.
Die Außenstation benutzt für den
Anschluss der Innensprechstellen
den Bus BPT
X2 TECHNOLOGY
, der
in einer einzigen verdrillten Telefon-
schleife alle für den Anlagenbetrieb
erforderlichen Signale überträgt.
Über die Serienschaltung an die
erste Außenstation ist das Hinzu-
fügen drei weiterer Außenstationen
sowohl für Videosprech- als auch
Haussprechanlagen ohne die Benut-
zung weiterer Geräte (Wählschalter,
Verteiler) möglich.
Die Außenstation verfügt über einen
geeigneten Sitz für den Set Leucht-
meldung für Anlage besetzt KHSO
und für 3 Rufsets KHPS (oder 2 Sets
KHPD).
Die Außenstation ist folgenderweise
ausgestattet:
- Lautsprecher- und Mikrofonsatz;
- LED mit Infrarotlicht für die
Beleuchtung des Subjekts;
- drei Spannungsteiler für die folgen-
den Funktionen (Abb. 4-5):
Regelung der Lautstärke an der
Außenstation;
Regelung der Lautstärke an der
Innensprechstelle;
P1
Regelung (von 1 bis 15 s) der Akti-
vierungsdauer des Elektroschlosses.
Die Außenstation ist mit einem
Tonsignal, der den Besetztzustand
der Anlage meldet, und mit einem
aktiven Elektroschloss ausgestattet.
Die mitgelieferten Kabel sorgen für
einen leichten Anschluss an die ver-
schiedenen Geräte der Außenstation.
Funktion der Klemmleisten
Klemmleiste M1
14÷18V DC
Stromversorgung
Ausgang Elektroschloss
Türöffnertaste
–
Masse für Elektroschloss
Ausgang Zusatzsteuerung 1
Ausgang Zusatzsteuerung 2
Ausgang Einschaltung der
Außenstation
B IN
Buseingang von anderen
Außenstationen
B OUT
Busausgang zu den Innen-
sprechstellen oder anderen
Außenstationen
Klemmleiste M2
3
Videosignal
4
Masse Videosignal
Funktion der Steckverbinder
Steckverbinder CN1 mit 5 Schaltstel-
lungen:
für den Anschluss an das
Tableau HEP/306 oder HEP/312D.
Steckverbinder CN3 mit 3 Schaltstel-
lungen:
für den Anschluss an die
Tasten KHPS oder KHPD.
1-rot:
an die Taste Nr.2.
2-orange:
an die Taste Nr.3.
3-gelb:
an die Taste Nr.4.
ACHTUNG. In Anlagen mit mehreren
Außenstationen ist die Beibehaltung