background image

7

La= distanza tra il dispositivo alimentato e la targa
Lb= distanza tra la targa ed l’elettroserratura
Lc= distanza tra l’alimentatore e il dispositivo alimentato

La= distance between powered device and entry panel
Lb= distance between entry panel and solenoid lock
Lc= distance between power supplier and powered device

Tabella distanze con l’alimentatore VPSW2 
Table of distances with VPSW2 power supplier

Tab.1

Sezione dei conduttori

Wire cross-section

L

(La+Lb+Lc)

m

L1

(La+Lc)

m

0,5 mm

2

25 m

50 m

1 mm

2

50 m

100 m

1,5 mm

2

100 m

L+

+

Aux

VEPW2

L+

-

12V

L–

L–

VRW2

Lb

La

1

– 14V +

230V

+

14V

230V

VPSW2

Lc

Aux

20

CONFIGURAZIONE BASE.

BASIC CONFIGURATION.

Содержание b-red VKW200

Страница 1: ...I SEC 14V 230V 230V 50Hz 18V VKW200 0704020 The trademark b red is property of Bpt S p A Imported by Bpt S p A for EU market Via Roma 41 30020 Cinto Caomaggiore VE Italy www bpt it KIT VIDEO ENTRY SYSTEM ...

Страница 2: ...2 ...

Страница 3: ...asso fig 6 o fig 7 utilizzando le viti ed i tasselli in dotazione Nel caso i cavi arrivino da una canalina esterna alla parete far passare il cavo in corrispondenza delle frecce come indicato in figura 8 Su pareti non perfettamente piane evi tare il serraggio eccessivo delle viti Effettuati i collegamenti vedere ISTRU ZIONI PER IL COLLEGAMENTO e posi zionare il videocitofono sul supporto in metall...

Страница 4: ... the video entry control panel to a solenoid lock maintained by a continuous flow of current or one controlled by an im pulse generating equipment 12 V AC or DC 0 5 A It is best to install the panel in a shel tered area to avoid direct rain or drip ping VPSW2 power supplier This consists of an AC DC converter which is electronically and thermally protected against overloads and short circuits It p...

Страница 5: ...5 1 CN1 AUX AUX L L 9 L L 4 2 500 mm 170 mm 710 mm 170 mm 140 mm 530 mm 140 mm h 500 mm 3 5 6 7 CN1 8 10 11 12 L L L L 13 ...

Страница 6: ...6 230V 14v 17 19 14 2 1 15 PRI SEC 14V 230V 230V 50Hz 14V 18 54 83 45 45 54 58 16 ...

Страница 7: ...distance between entry panel and solenoid lock Lc distance between power supplier and powered device Tabella distanze con l alimentatore VPSW2 Table of distances with VPSW2 power supplier Tab 1 Sezione dei conduttori Wire cross section L La Lb Lc m L1 La Lc m 0 5 mm2 25 m 50 m 1 mm2 50 m 100 m 1 5 mm2 100 m L Aux VEPW2 L 12V L L VRW2 Lb La 1 14V 230V 14V 230V VPSW2 Lc Aux 20 CONFIGURAZIONE BASE BA...

Страница 8: ...8 ...