-24-
1. Receive the 16-step gray scale computer signal with
Input 1 [RGB(Analog)]
mode.
2. Enter the service mode.
3. Connect a digital voltmeter to test point “
TP531
” (+)
and chassis ground (-).
4. Select group no. “
4
”, item no. “
6
” and change data
value to adjust the voltage to be
7.50
±0.1Vdc.
5. Connect a digital voltmeter to test point “
TP561
” (+)
and chassis ground (-).
6. Select item no. “
7
” and change data value to adjust
the voltage to be
7.50
±0.1Vdc.
7. Connect a digital voltmeter to test point “
TP501
” (+)
and chassis ground (-).
8. Select item no. “
8
” and change data value to adjust
the voltage to be
7.70
±0.1Vdc.
v
Video Center adjustment
Electrical Adjustments
1. Receive the 16-step gray scale computer signal with
Input 1 [RGB(Analog)]
mode.
2. Enter the service mode.
3. Select group no. “
500
”, item no. “
0
” and change data
value to adjust the
green
noise on the white 0% area
of screen to the first point of the deepest green.
4. Select item no. “
1
” and change data value to adjust
the
blue
noise on the white 0% area of screen to the
first point of the deepest blue.
4. Select item no. “
2
” and change data value to adjust
the
red
noise on the white 0% area of screen to the
first point of the deepest red.
n
PC Pedestal adjustment
1. Receive the 16-step gray scale computer signal with
Input 1 [RGB(Analog)]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP533
” (+) and
chassis ground (-).
4. Select group no. “
4
”, item no. “
18
” and change data
value to adjust amplitude “
a
” to be
10.0
±0.1V.
4. Select item no. “
21
” and change data value to adjust
amplitude “
b
” to be
4.0
±0.1V.
3. Connect an oscilloscope to test point “
TP503
” (+) and
chassis ground (-).
4. Select group no. “
4
”, item no. “
20
” and change data
value to adjust amplitude “
a
” to be
10.0
±0.1V.
5. Select item no. “
23
” and change data value to adjust
amplitude “
b
” to be
4.0
±0.1V.
(a)
(b)
b
PSIG adjustment
1. Receive the 16-step gray scale computer signal with
Input 1 [RGB(Analog)]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+) and
chassis ground (-).
4. Select group no. “
4
”, item no. “
0
” and change data
value to adjust waveform “
a
” to be minimum ampli-
tude.
5. Connect an oscilloscope to test point “
TP561
” (+) and
chassis ground (-).
6. Select item no. “
1
” and change data value to adjust
waveform “
a
” to be minimum amplitude.
7. Connect an oscilloscope to test point “
TP501
” (+) and
chassis ground (-).
8. Select item no. “
2
” and change data value to adjust
waveform “
a
” to be minimum amplitude.
(a)
White Level
m
PC Gain adjustment
Содержание MP-45
Страница 60: ...60 IC Block Diagrams BH3540 Volume Control IC1652 BA7078AF Sync Detector IC5304...
Страница 61: ...61 CXA2151Q RGB Matrix IC4101 CXA7004R LCD Driver IC501 IC531 IC561 IC1501 IC1531 IC1561 IC Block Diagrams...
Страница 62: ...62 CXD3531R Digital Signal Driver Timing Generator IC401 ICS1523M Clock Driver IC4231 IC Block Diagrams...
Страница 64: ...64 IC Block Diagrams LB1641 Motor Drive IC1602 IC1611 LB1645 Motor Drive IC1601...
Страница 66: ...66 M62393 D A IC212 M62399 D A IC7801 IC Block Diagrams ML60851 USB Interface IC9801...
Страница 68: ...68 IC Block Diagrams STR Z2156 Power Switching IC651 Sii169CT DVI Interface supporting HDCP IC8001...
Страница 69: ...69 IC Block Diagrams TB1274AF Video Decoder IC3101 TA1370FG Sync Separator Frequency Counter IC7301...
Страница 70: ...70 TDA7056 Audio Output IC1631 IC1632 TC90A69F 3 Line Digital Comb Filter IC2101 IC Block Diagrams...
Страница 108: ...MR3 MP 45t00 Mechanical Parts List 108 68 45 23 24 45 45 45 68 a 68 b 23 b 23 a 23 c 24 a 23 d...
Страница 110: ...MR3 MP 45t00 110 Optical Parts List 47 55 46 46 69 b Red 69 c Green 69 d Blue 69 47 47 47 69 a 69 e G B Red no use...
Страница 116: ...Diagrams Drawings MR3 MP 45t00...