29
8. Important hints
8.1
First start-up
First start-up of the machine has to be
Attention:
carried out by the BÖWE service organization.
Before opening the control
box or removing panelling,
turn
main switch to "0".
8.1.1
Filling the machine with solvent
(emission-free filling is standard)
Only use stabilized, neat TETRACHLOROETHANE
Attention:
(Perc) in accordance with DIN 53978.
Before turning on the
pump must be filled with solvent.
Required solvent amount for the first filling:
P 240 /P 300 USA:
220 l (360 kg) 58.1 USgal (794 lb)
P 300 /P 350 USA:
260 l (420 kg) 68.7 USgal (926 lb)
The emission-free filling takes place in a closed system:
-
Screw off pump line cap
Attention:
-
Connect hose between barrel (bottom) and
Perc has a high
pump suction side
liposolubility. When using
perc wear gloves and
-
Connect hos (gas displacement line)
subsequently put on
between barrel and water separator
cream on hands. No
smoking. If perc gets
-
Open ball valve
into the eyes seek further
medical advice.
-
Start program P37
-
Tanks fill up overflowing one into the other
-
Once the tanks are full, stop program P37
-
Close ball valve
-
Remove hose connection from barrel
-
Screw cap back on pump pipe
!
!