27
7. Connection
Allowed voltage range
Attention:
Before switching on the machine the power supply at the machine must be measured.
If power supply divates from the international standard, an autotransformer has to be
installed.
At the electrical connection of the dry-cleaning machine the following voltage ranges must be
observed.
1.
Main supply (according to DIN IEC 38):
Range
primarily 400 V mains primarily 230 V mains
not allowed; external adjustment necessary
< 360 V
< 207 V
normal range
MIN: - 10,0 %
360 V to 424 V
207 V to 244 V
MAX: + 6,0 %
not allowed; external adjustment necessary
> 424 V
> 244 V
2.
Computer control with power supply:
Range
Primarily 230 V - mains
not allowed; external adjustment necessary
< 207 V
normal range
207 V - 244 V
703904-18-0
not allowed; external adjustment necessary
> 244 V
L1
L2
L3
N
U
3x400V
L1
L2
L3
U
3x230V