User manual
eDAS
Enhanced Data Acquisition System
Rev.
EN-02_18 AVC
Date:
(IT 21_03_16 rev. 2 AM)
- 11 -
Fig. 3
–
Input Channels Configuration
1 to 8 Channel Configuration
Sensor
Type
Jumper Inputs
Supply Jumpers
Terminal
board
(Fig. 2)
S7
–
S8
–
S9
–
S10
–
S11
–
S12
–
S13
–
S14
S3
–
S4
–
S5
–
S6
–
S15
–
S16
–
S17
–
S18
J3-J4-J5-J6-
J10-J11-J12-
J13
VA
CS
VR
(2.5 V)
VS
(14 V)
1 2
3
Potenziometric
Open
Open
Closed
+
V
+
S
GND
Voltage output
0 .. 2,5V
Open
Open
Closed
+
V
+
S
GND
Voltage output
0 .. 5V
Closed
Closed
+
V
+
S
GND
Current Output
2-wire
4..20 mA
Closed
Closed
+
V
G
N
D
Current Output
3-wire
4..20 mA
Closed
Closed
+
V
+
S
GND
A TYPICAL CHANNEL
J3 =
Sensor terminal
S3 =
Supply configuration
Close S3 sideward VR or VS (see table)
S7 =
Input Configuration (see table)
- Open =
Input range: max 2,500 Volt
- Closed towards VA
= Input range: 2,5 to 5,0 Volt
Note: In this mode the Input voltage is halved
- Closed towards CS
= Input range 4 .. 20 mA
on 100
Ω
resistor