- 46 -
COLD UNITS
y
Controller operation
:
1
2
3
4
5
6
- Turn on by key
6
.
- Turn on or turn off the light by key
3
.
- Adjusting the controller temperature :
* press key
5
. Controller temperature displayed.
* set the new temperature using the keys
1
and
4
.
* confirm by pressing key
5
.
- Displaying the minimum and maximum temperatures :
* press
4
for the minimum temperature --> “Lo” displayed followed by the minimum temperature recorded --> press
4
or wait
for 5 seconds.
* press
1
for the maximum temperature --> “Hi” displayed followed by the maximum temperature recorded --> press
1
or wait
for 5 seconds.
- Start manual defrosting :
* press
2
for more than 2 second.
y
Units with refrigerated display units
(853133/853193/853104/853194/853105/853195/853106/853196/853403/853493/
853404/853494/853405/853495) :
These units keep previously cooled food at a temperature of between 0 and 3°C, and at a maximum temperature of 8°C, with a room
temperature of 25°C, for 1 hour 30 minutes after opening of the curtains.
Fitting the shelves (Figure 2)
Allow to cool for 2 hours with the curtains closed, before use.
y
Static cold unit
(853033/853093/853024/853094/853025/853095/853026/853096/853223/853293/853224/853294/853225/
853295) and buffet (853494/853595) :
These units keep previously cooled food at a temperature of between 0 and 3°C, and at a maximum temperature of 8°C, with a room
temperature of 25°C, for 1 hour.
Allow to cool for 2 hours before use.
PRECAUTIONS FOR USE
These units are not intended to be used by people (including children) with reduced physical, sensory or mental abilities, or by people
with no experience or knowledge, unless they are supervised or have been given prior instructions on how to use the unit, by a person
responsible for their safety. Children’s should be supervise to ensure that they do not play with the unit.
MAINTENANCE
y
Do not clean the units using a jet.
y
Painted, wooden or metal parts: use soapy water and a sponge.
y
Glass parts : window cleaning product. Do not use abrasive or scouring sponges.
y
Cold units :
- Every 4 months, make sure that the condenser is not blocked.
- Every year, check :
* the condenser fan for operation
* the evaporator fans for operation (to access the evaporator and fans, remove the grey plate (Figure 3)).
This equipment carries the recycling symbol in accordance with Directives 2002/95/CE and 2002/96/CE relating to Waste Electrical or
Electronic Equipment (DEEE or WEEE) At the end of its working life the equipment should be recycled in accordance with the regulations
that are in force in the country of its installation
.
Содержание 851022
Страница 9: ... 9 ALIMENTATION ÉLECTRIQUE POWER SUPPLY STROMVERSORGUNG Meubles Units Geräte réf 854112 854122 ...
Страница 10: ... 10 ALIMENTATION ÉLECTRIQUE POWER SUPPLY STROMVERSORGUNG Meubles Units Geräte réf 854123 854124 ...
Страница 15: ... 15 ALIMENTATION ÉLECTRIQUE POWER SUPPLY STROMVERSORGUNG Meubles Units Geräte réf 853594 853595 ...
Страница 16: ... 16 ALIMENTATION ÉLECTRIQUE POWER SUPPLY STROMVERSORGUNG Meubles Units Geräte réf 854510 854520 ...
Страница 17: ... 17 COMPOSANTS D ASSEMBLAGE FITTING COMPONENTS ZUSAMMENSTELLUNGSBESTANDTEILE ...
Страница 18: ... 18 COMPOSANTS D ASSEMBLAGE FITTING COMPONENTS ZUSAMMENSTELLUNGSBESTANDTEILE ...
Страница 41: ... 41 ASSEMBLAGE DES PLINTHES FITTING OF THE BASEBOARD ZUSAMMENFÜGEN DER FUSSLEISTEN ...
Страница 42: ... 42 FIGURE 2 FIGURE ABBILDUNG FIGURE 3 FIGURE ABBILDUNG FIGURE 1 FIGURE ABBILDUNG ...
Страница 74: ... 74 ...
Страница 75: ... 75 ...