Dari-Kool III-120 Instructions 

 1E-138B

Dari-Kool

®

 III-120 

Heat Recovery 

System

Instructional Content and Purpose

These  instructions  aim  to  aid  those  responsible  (outlined  under 

“Responsibilities”) for installing, operating, maintaining, troubleshooting, 

and servicing this product.

Responsibilities

Procedures  in  these  instructions  are  to  be  performed  according  to 

applicable codes (state, local, and other) by the person(s) qualified 

(licensed, if applicable) to do so—that is:

•  Welding must be done by a qualified welder.

•  High-voltage AC power wiring must be done by a qualified (licensed) 

electrician in compliance with the latest edition of the ANSI/NFPA 

Standard 70, National Electrical Code, (USA) or either LVD 

2006

95/

EC or EMC 

2004

/

108

/EC (Europe) and in compliance with  

the l

ocal wiring codes as applicable.

•  Other installation, major maintenance, and service work must be 

done by an authorized BouMatic dealer.

•  Product/system  checkout  and  troubleshooting  steps  are  to  be 

performed by an authorized BouMatic dealer.

•  Deviation from these instructions could affect product performance 

or create a hazardous situation.  Under no circumstances will 

BouMatic be responsible for any problems caused in whole or 

in part by any deviation from the procedures specified in these 

instructions without prior written approval from BouMatic.

•  Operation  steps  may  be 

performed by the owner/

operator once the dealer 

or  technician  has  suc

-

cessfully  finished  the 

product/system checkout.  

The  owner/operator  is 

responsible  for  properly 

operating,  maintaining, 

and monitoring the prod

-

uct/system to ensure that 

it works properly.

Close  compliance  with  the 

procedures herein is essential for the owner to get maximum benefit 

from the product/system.

Disclaimers

No  warranties  are  contained  in  these  instructions.   The  division  of 

responsibilities, stated above, is a general reminder of those provisions 

in the applicable dealer contract and does not change any agreement 

between BouMatic and the dealer.  Information in these instructions is 

not all-inclusive and cannot cover all unique situations.

I

nstallation Instructions

 P.O. Box 8050

 Madison, WI, 53708-8050

 USA

 Telephone: (608) 222-3484

 Fax: (608) 222-9314

 Remicourt 31, Rue Jules Melotte

 B 4350 Remicourt

 Belgium

 Telephone: +32 (0)19 544 266

 Fax: +32 (0)19 545 544

 www.boumatic.com

1. 

Preparation

If something is missing, contact the BouMatic Customer 

Service Department immediately.

1.1

 Reviewing Personal Safety Messages

Follow the safety messages below and throughout this 

booklet to prevent possible bodily injury.  Safety should 

be  everyone’s  primary  concern.    Note  that  the  owner 

is  responsible  for  replacing  safety  labels  should  they 

become illegible.

Provide  positive,  lockable  disconnects  to  prevent 

unintended  application  of  electrical  power  to  the 

equipment.  Refer to national regulations for proper lock-

out procedures for equipment service or repair. 

- CAUTION —————————–––——————–––––

Failure to properly install the discharge line from the safety relief 

valve  could  result  in  hot  water  spraying  on  a  person,  causing 

burns.

Introduction

The Dari-Kool

®

 III-120 is an insulated water storage tank that 

is a refrigerant heat recovery device. It provides two high-

temperature water outputs and an electric auxiliary heating 

element. An optional water valve is available.

Contents

Introduction ......................................................................................................................1

1. 

Preparation .....................................................................................................................1

1.1

 Reviewing Personal Safety Messages ..........................................................1

1.2

 Control Circuit ......................................................................................................2

1.3  

Control Settings ..................................................................................................2

1.4

 Optional Water Valve  ........................................................................................2

2.

 Choosing the Location for the Dari-Kool-120 ....................................................2

3.

 Installing the Dari-Kool III-120 .................................................................................2

4.

 Installing the Refrigeration System .......................................................................3

4.1 

Installation Layout ..............................................................................................3

4.2

 Refrigerant ............................................................................................................3

4.3

 Refrigerant  Lines ................................................................................................4

5.

 Wiring ...............................................................................................................................5

Содержание Dari-Kool III-120

Страница 1: ...em Disclaimers No warranties are contained in these instructions The division of responsibilities stated above is a general reminder of those provisions in the applicable dealer contract and does not...

Страница 2: ...idelines must be observed 1 The Dari Kool III 120 should be in a clean dry place as close as possible to the compressor to minimize the refrigerant line lengths 2 It should be located with adequate cl...

Страница 3: ...power will have to be applied to the valve in order to close it while checking for leaks DO NOT apply power to the heating element unless it is covered with water 7 The Dari Kool III 120 has dual mag...

Страница 4: ...and condensor and to drop down from the compressor discharge to form a 6 152 mm trap to prevent oil and liquid refrigerant from accumulating on the discharge valve plate When two circuits of the Dari...

Страница 5: ...t used control wires for valve must be isolated The equipment ground must be completed The wiring must conform to local and state electrical codes and must be installed by qualified personnel The diag...

Страница 6: ...efrigerant capacity Condensing unit not to exceed 15 tons 53 kW of R 22 R 404 or R 407 or 7 5 tons 26 kW of R 134A Refer to table for recommended line sizing Figure 6 1 ton 3 5 kW of refrigerant capac...

Страница 7: ...condensing unit capacity of 1 ton each Figure 9 Dari Kool III 120 in parallel with a large condensing unit Add additional Dari Kool III 120 as required Condensing unit is not to exceed 30 105 kW tons...

Страница 8: ...d 15 tons 52 7 kW of R 22 R 404 or R 407 or 7 5 tons 26 kW tons of R 134A Minimum of 3 ton 10 5 kW condensing unit Figure 10 Dual condensing units dual temperature Each condensing unit does not to exc...