Dari-Kool III-120 Instructions
5
1E-138B
5.
Wiring
A separate 27 Amp, 240V branch circuit must be provided to
the Dari-Kool III-120 junction box. Fuse according to local
codes. A control circuit from the junction box to the control
valve if used. If optional control valve is not used, control
wires for valve must be isolated. The equipment ground must
be completed. The wiring must conform to local and state
electrical codes and must be installed by qualified personnel.
The diagram is shown in Figure 5.
— ATTENTION ————————————————————
The tank must be full of water before the power is turned on. The
heating element will be damaged if energized even for a short
period of time while the tank is empty, thus voiding the warranty
on the heating element.
Figure 5. Wiring diagram