1:6 BOILER CONTROL PANEL
Fig 1 a
Boiler Control Panel (see Fig 1a)
1. Boiler control thermostat
2. Hot water thermostat
3. Boiler overheat/limit thermostat
4. Lockout indicator light - red
5. Mains indicator light - green
6. Limit indicator light - red
7. Heating ON indicator light - green
8. Summer/winter switch
9. System pressure indicator dial
10. Domestic water flow indicator light - green
11. Tank heating indicator light - green
1:6.1 Boiler Control Thermostat
The Boiler Control Thermostat controls the water temperature in the boiler. The recommended setting is
shown in
Fig 1a.
This thermostat automatically switches the burner ON & OFF to maintain the selected temperature. The
burner is lit by an automatic ignition system and therefore there is no pilot flame.
The Boiler should not be operated below 60°C, as this will cause corrosion which will reduce the life of the
boiler.