37355-0-0217
PRODUCT SPECIFICATIONS
Table 1 - Air Shutter Opening - Natural Gas Models
Model
Air Shutter Opening
VFLL60SP90LN
1/16 inch
Table 2 - Air Shutter Opening - LP Gas Models
Model
Air Shutter Opening
VFLL60SP90LP
1/4 inch
VFLL60SP90LP (LP GAS)
VFLL60SP90LN (NAT GAS)
Input BTU/HR Maximum
38,500
40,000
Input BTU/HR Minimum
29,000
25,000
Orifice
1.8mm
#32
NOTICE:
Air shutter settings are factory set and may not be altered.
GAS SUPPLY PRESSURES (inches water column)
GAS TYPE
MAXIMUM
MINIMUM
MANIFOLD
NAT
10.5
7.0
3.5
LP
13.0
11.0
10.0
HOMEOWNER REFERENCE INFORMATION