7.0 

Specifications 

 

 

Electric motor

 

 

220/380 V -3 PH -50 Hz 

Electric motor power 

0.75 kW 

Inspection torch and control circuit voltage 

24 V 

Inspection torch LED cluster power 

2.25 W 

Hydraulic working pressure 

200 bar 

Maximum force applied to moving plate 

12.8 kN 

Admissible load on moving plate 

1500 kg 

Minimum lateral travel of moving plate 

40mm 

Minimum plate rotation 

8° 

Dimensions – Play Detector (L x W x H) 

600 x 605 x 42 mm

 

Dimensions – Pedestal (L x W x H) 

220 x 420 x 1200 mm 

Hydraulic oil and capacity 

ISO 32 / 3 Ltr 

Hydraulic oil replacement schedule 

Annually  

Noise level during operation 

<70dB

 

Wireless inspection torch operating distance 

Max 50m 

Wireless inspection torch charging time 

4 Hours (Approx) 

Wireless inspection torch battery voltage 

7.2 V 

Wireless inspection torch operating time (without charge) 

1.5 hours (Approx) 

 

 

 

 

Содержание PD301

Страница 1: ...r 1 PD301 Hydraulic Wheel Play Detector USER MANUAL Garage Equipment Association Boston Garage Equipment 199 New Road Rainham Essex RM13 8SJ United Kingdom T 44 0 1708 525585 F 44 0 1708 525408 info b...

Страница 2: ...scription 3 2 0 Safety 3 2 1 Special Notice 4 3 0 Operation 5 3 1 The Pedestal 5 3 2 Main Power 6 3 3 Emergency Stop 6 3 4 Mode Switching 7 3 5 Plate Operation 8 3 6 Inspection Torch 9 4 0 User Mainte...

Страница 3: ...e and anti clockwise The equipment comprises three items The Pedestal the Play Detector and the Handheld Torch Control Operation of the Play Detector can be achieved by using the membrane keypad fitte...

Страница 4: ...hoist supplied by any company other than BOSTON GARAGE EQUIPMENT or without written certification from BOSTON GARAGE EQUIPMENT that the PD301 is suitable for that hoist is considered improper use Appr...

Страница 5: ...ion after each button press in Continuous Mode or when the unit is re started To preserve energy and reduce pump motor wear the software will de activate the motor approximately 2 seconds after each o...

Страница 6: ...itched off every evening 3 3 Emergency Stop The Emergency Stop button can be pressed at any time to immediately stop the plate from moving Its function is to stop the motor and associated operational...

Страница 7: ...from another operator The inspection lamp at the front of the torch can still be operated as normal b Manual Continuous The Manual and Continuous modes allow the operator to change the way in which t...

Страница 8: ...ted the Continuous LED will show and the play detector will operate in the following way BUTTON DEPRESSED PLATE MOVEMENT LEFT Moves LEFT first and then RIGHT repeatedly until button release RIGHT Move...

Страница 9: ...selected The torch keypad is laid out as below Keypad Functionality Hardwired Torch The torch is programmed with a standard safety feature to prevent accidental operation of the Play Detector should...

Страница 10: ...nate the PD LED as before The operation is now the same as the hardwired version above The BATT LED will show when the torch battery requires charging In this case the torch should be placed in the ch...

Страница 11: ...elbase vehicles The cable is attached at the torch end by means of a 6 25mm lockable jack plug socket The socket is designed to unlatch at maximum pull to prevent damage to either the torch or pedesta...

Страница 12: ...on load bearing discs Using PTFE spray apply one spray to each disc in turn Underneath the main cross beam there are two more load bearing Nylatron supports Also apply a single spray to each support F...

Страница 13: ...may change For service and repair always contact your local distributor If the PD301 is being used for statutory MoT testing VOSA stipulate that the equipment is subject to annual service and calibra...

Страница 14: ...ivate emergency stop Deactivate circuit protector Power is on but no plate movement Emergency stop activated Deactivate emergency stop Wrong control selected Select desired control Torch does not swit...

Страница 15: ...Model number is required Required delivery date Part No Description B3033 Nylatron load bearing discs set of 20 B3034 Stainless moving top plate B3035 Countersunk screws for moving cover plate set of...

Страница 16: ...late 1500 kg Minimum lateral travel of moving plate 40mm Minimum plate rotation 8 Dimensions Play Detector L x W x H 600 x 605 x 42 mm Dimensions Pedestal L x W x H 220 x 420 x 1200 mm Hydraulic oil a...

Страница 17: ...and Conditions are available on request It should be noted that fair wear and tear and the following parts are EXCLUDED from the warranty The flexible coiled data cable from pedestal to torch The fle...

Страница 18: ...OS0295 User Manual PD301 Play Detector 18 Boston Garage Equipment 199 New Road Rainham Essex RM13 8SJ United Kingdom Tel 44 0 1708 525585 Fax 44 0 1708 525408 Email info boston ge com Web www boston g...

Отзывы: