After the monthly maintenance is complete, replace the moving plate and ensure that it is
tightly secured. On a regular basis the oil reservoir inside the pedestal should also be
checked. The level should always remain the same, but in the event of any leaks this may
change. For service and repair always contact your local distributor.
If the PD301 is being used for statutory MoT testing, VOSA stipulate that the equipment is
subject to annual service and calibration. This must be done by an APPROVED Boston
engineer and a contract should be in place with Boston or an approved agent for this work.
Apply PTFE lubrication
to the top surface of
the beam supports.
Apply GREASE
lubrication to the
sliding block and
channel, and main pin
on the underside of the
moving plate.