![background image](http://html1.mh-extra.com/html/boston-whaler/conquest-345/conquest-345_owners-manual_2796226124.webp)
3-31
345 Conquest
Section 3 • Systems & Components Overview & Operation
Section 3 • Systems & Components Overview & Operation
345 Conquest
R
Section 3 • Systems & Components Overview & Operation
!
DANGER
DO NOT handle the actuator. The fire suppression
system is under pressure (195 psi.). Accidental
discharge may result in death or serious injury.
Fire Suppression System
!
DANGER
Inhalation of high concentrates of the contents
of the fire suppression tank may cause sudden
death without warning.
Skin contact will require flushing of the area with
water for at least 15 minutes. Seek immediate
medical assistance.
NOTICE
The fire extinguishant contained in this unit
is CHLOROTETRAFLUORATHANE, None of the
components in this material is listed by major
health associations as a carcinogen. Toxic
by-products are produced when this agent
extinguishes fire. Avoid breathing these fumes.
Your boat has a USCG approved automatic fire
suppression system which is located on the equipment
bulkhead in the port bilge and can be accessed by
lifting the mechanical hatch in the aft cockpit deck.
The system will activate when the temperature in the
enclosed area reaches 165°F (74°C).
When activated there will be a bang, (similar to small
arms fire) followed by a rushing air sound.
Shore Power Load Management
Your boat is equipped with many devices that require
AC power for their operation. While many of these
devices are continuous use items, others are not.
The design of the electrical system has been
optimized to support the most commonly used
equipment. However, there may be situations where
the operator will need to power off certain appliances
based on load requirements, shore power connections
and/or generator operation.
To obtain the most power for your appliances, it
is best to use the “GENERATOR” and “SHORE
POWER 2” combination which will deliver a higher
load capability.
Battery Charging
In addition to supplying AC power to your boat, shore
power hookup gives you the ability to charge your
batteries without running the engines.
The system is automatic and little or no maintenance
is required. The battery charger can be accessed
through the equipment hatch in the aft cockpit deck.
Isolation Transformers
Your boat is equipped with isolation transformers.
The boat’s electrical system and grounding conductor
are not actually connected to the dockside system.
The isolation transformer transfers power from the
dockside electrical system to the boat’s electrical
system by magnetic coupling. This means there is
no direct electrical connection between the earth-
grounded shore AC power and the boat AC power.
Isolating the power this way has several benefits:
The above statement pertains to the 345
Conquest ONLY.
Other boat systems may or may not provide
shock protection to swimmers.
NEVER ALLOW SWIMMING in close proximity to
other boats which may be running AC electrical
systems.
!
DANGER
REFER TO THE MANUFACTURER’S MANUAL IN
YOUR OWNER’S MANUAL PACKET FOR COMPLETE
INSTRUCTIONS AND WARRANTY.
• Eliminates shock hazards to people swimming
around the boat.
• Prevents reverse polarity due to a miss-wired
shore power pedestal providing further
protection to people onboard as well as
sensitive AC appliances.
• Prevents galvanic current corrosion due to the
direct connection to AC shore power.
Содержание CONQUEST 345
Страница 21: ...xix 345 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 93: ...2 46 Section 2 General Information 345 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 149: ...4 15 Section 4 Electrical System 345 Conquest Section 4 Electrical System Batteries Standard Boat Fig 4 15 1...
Страница 150: ...4 16 345 Conquest Section 4 Electrical System Batteries Joystick Steering Option Fig 4 16 1...
Страница 151: ...4 17 Section 4 Electrical System 345 Conquest Section 4 Electrical System DC MDP Standard Boat Fig 4 17 1...
Страница 152: ...4 18 345 Conquest Section 4 Electrical System DC MDP Joystick Steering Fig 4 18 1...
Страница 153: ...4 19 Section 4 Electrical System 345 Conquest Section 4 Electrical System AC Power 120V 60Hz Schematic Fig 4 19 1...
Страница 154: ...4 20 345 Conquest Section 4 Electrical System AC Power 220V 50Hz Fig 4 20 1...
Страница 155: ...4 21 Section 4 Electrical System 345 Conquest Section 4 Electrical System Courtesy Accent Lights Fig 4 21 1...
Страница 156: ...4 22 345 Conquest Section 4 Electrical System Cabin O H and Accent Lights Fig 4 22 1...
Страница 158: ...4 24 345 Conquest Section 4 Electrical System Wipers and Washers Fig 4 24 1...
Страница 160: ...4 26 345 Conquest Section 4 Electrical System Waste System Fig 4 26 1...
Страница 161: ...4 27 Section 4 Electrical System 345 Conquest Section 4 Electrical System Windlass Fig 4 27 1...
Страница 162: ...4 28 345 Conquest Section 4 Electrical System Trim Tabs Fig 4 28 1...
Страница 163: ...4 29 Section 4 Electrical System 345 Conquest Section 4 Electrical System Bow Thruster Fig 4 29 1...
Страница 164: ...4 30 345 Conquest Section 4 Electrical System Courtesy Outlets Blower Extinguisher and 30A reel Outlets Fig 4 30 1...
Страница 165: ...4 31 Section 4 Electrical System 345 Conquest Section 4 Electrical System Pumps Sheet 1 Fig 4 31 1...
Страница 166: ...4 32 345 Conquest Section 4 Electrical System Pumps Sheet 2 Fig 4 32 1...
Страница 167: ...4 33 Section 4 Electrical System 345 Conquest Section 4 Electrical System Pumps Sheet 3 Fig 4 33 1...
Страница 168: ...4 34 345 Conquest Section 4 Electrical System V Berth Schematic Fig 4 34 1...
Страница 169: ...4 35 Section 4 Electrical System 345 Conquest Section 4 Electrical System Shore Power 120V Schematic Fig 4 35 1...
Страница 170: ...4 36 345 Conquest Section 4 Electrical System Shore Power 230V 50HZ Fig 4 36 1...
Страница 171: ...4 37 Section 4 Electrical System 345 Conquest Section 4 Electrical System Stereo Basic Option Fig 4 37 1...
Страница 172: ...4 38 345 Conquest Section 4 Electrical System Stereo Premium Option Fig 4 38 1...
Страница 173: ...4 39 Section 4 Electrical System 345 Conquest Section 4 Electrical System Stereo Upper Station Option Fig 4 39 1...
Страница 174: ...4 40 345 Conquest Section 4 Electrical System Heater CO Monitor Fig 4 40 1...
Страница 175: ...4 41 Section 4 Electrical System 345 Conquest Section 4 Electrical System Generator 120V 60Hz Fig 4 41 1...
Страница 176: ...4 42 345 Conquest Section 4 Electrical System Generator 230V 50Hz Fig 4 42 1...
Страница 177: ...4 43 Section 4 Electrical System 345 Conquest Section 4 Electrical System Port AC Harness Fig 4 41 1...
Страница 178: ...4 44 345 Conquest Section 4 Electrical System STBD AC Harness Fig 4 42 1...
Страница 179: ...4 45 Section 4 Electrical System 345 Conquest Section 4 Electrical System Port DC Harness Fig 4 43 1...
Страница 180: ...4 46 345 Conquest Section 4 Electrical System STBD DC Harness Fig 4 44 1...
Страница 181: ...4 47 Section 4 Electrical System 345 Conquest Section 4 Electrical System Battery Layout Fig 4 45 1...
Страница 182: ...4 48 345 Conquest Section 4 Electrical System Windlass Harness Fig 4 46 1...
Страница 183: ...4 49 Section 4 Electrical System 345 Conquest Section 4 Electrical System Headliner Harness Fig 4 47 1...
Страница 184: ...4 50 345 Conquest Section 4 Electrical System Bow Thruster Harness Fig 4 48 1 Hardtop Harness Fig 4 48 2...
Страница 206: ...5 22 Section 5 Care Maintenance 345 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...