background image

305 Conquest-Owner’s Manual

Section 6 - Water & Waste System

Standard waste level

indicator panel

This panel will give you an indication of the level of waste
that is in the holding tank. There are four (4) levels of
indication, empty, low, mid and full.  When the indicator
reads full; you should have the holding tank emptied.
MACERATOR
The 305 Conquest waste system also incorporates the
use of a  macerator. The macerator pump draws solid
and liquid waste from the holding tank and processes it
prior to discharging it overboard through a lockable
seacock. The pump is designed to handle waste, toilet
tissue and facial tissue but will not pump solid objects.
It is important that you close your macerator discharge
seacock prior to using the shoreside discharge function.
Contact your dealer or Coast Guard station for infor-
mation on overboard discharge and its penalties.

Head System

Both intake and discharge seacocks should always be
in the closed position when the toilet is not in use.
Failure to do so could result in flooding, property dam-
age and loss of life.

CAUTION

This boat is equipped with an optional overboard dis-
charge valve. Discharging of sewage directly overboard
is for use where approved only.

NOTICE

There are severe state and federal penalties for dis-
charging raw sewage and solid waste in waters where
it is not permitted. Check with local authorities on where
this is permissible, if possible employ the use of a
shore side discharge.

NOTICE

!

!

!

HEAD

SYSTEM

Your 305 Conquest has a head com-
partment located on the aft starboard
side of the cabin. It is fitted with a
VacuFlush® waste containment system
that includes:  The VacuFlush® toilet,

vent, holding tank, vacuum pump and associated  hoses
and clamps. Complete operating and maintenance in-
structions can be found in the VacuFlush® operations
manual.
OPERATION
Energize the switch marked “VACUUM FLUSH” on
the DC MDP. Turn the keyswitch located in the head
compartment, (below the tankwatch panel) clockwise.
Your vacu-flush toilet has a flush lever on the lower left
side of the bowl. Raise the lever to fill the bowl with
water, more water is required when flushing solids. To
flush, push the lever down for three (3) seconds or until
the contents have cleared the bowl. The flush lever will
automatically return to a neutral position. If the contents
of the toilet were not emptied, you will have to wait till
there is sufficient vacuum (the vacuum pump stops run-
ning) before attempting to clear the bowl.
DOCK-SIDE DISCHARGE:
The Dock-side discharge deck plate for the 305 Con-
quest is located on the port side of the gunwale and is
marked “WASTE”.  Access to the port is gained by use
of a special key that is included in the owners manual
packet.

The dockside facility will have a connection to fit your
boat. Shore side discharge is a preferred method
of waste disposal.
This keyswitch panel can be used when you are ready
to discharge waste into the holding tank.

EMPTY

LOW

MID

FULL

T A N K W A T C H

OVERBOARD
DISCHARGE

48

Содержание 305 conquest

Страница 1: ...MODELS OR TO DISCONTINUE MODELS SHOULD CHANGES OR MODIFICATIONS TO THE MODELS BE MADE BOSTON WHALER IS NOT OBLIGATED TO MAKE SIMILAR CHANGES OR MODIFICATIONS TO MODELS SOLD PRIOR TO THE DATE OF SUCH C...

Страница 2: ...end on boats consistently choose Boston Whaler because of their seaworthiness dependablility and the inherent safety of a hull that won t sink even if severely damaged Boston Whalers are built to last...

Страница 3: ...ergency Operation 72 Manual Deployment Lowering 72 Circuit Protection 72 Section 10 Maintenance Log Notes Maintenance Log Notes 74 305 Conquest Owner s Manual Section 1 305 Conquest Table of Contents...

Страница 4: ...onWhaler BostonWhaler will repair or replace any accessories manufactured and installed by Boston Whaler that are defective in factory materials and or workmanship which are reported within one year f...

Страница 5: ...g factory specified procedures 9 use of improper trailer 10 any Boston Whaler boat used for Commercial Puposes i e more than 50 usage for business or revenue producing purposes 11 any representation o...

Страница 6: ...s shooting high density foam into a closed mold system The foam ex pandstofillvoidsinthehull andwhenthefinishedprod uct is pulled from the mold the deck and the hull are chemicallybondedtoformasolid i...

Страница 7: ...MinimumHorsepower 400 HP 298 kw FuelCapacity 300 Gal U S 1135 L DieselFuelCapacity optional 15 Gal U S 56 8 L Water Capacity 60 Gal U S 227 1 L Waste Capacity 10 Gal U S 37 8 L Waterline Specification...

Страница 8: ...tiMax Only 22 Motorwell Drain Port Starboard 23 Dual 225 CXL DTS Verado 4 stroke Engines Std 24 Motorwell Access Hatch 25 Telescoping Swim Ladder w Lid 26 Starboard Engine Oil Fill OptiMax Only 27 Sta...

Страница 9: ...ump 21 Battery Box 2 Port 22 Raw Water Pump 23 Livewell Seacock Pump 24 Downrigger Weight Holders 2 Port 2 Starboard 25 AftBilgePump2000GPH 26 3 Gal Oil Reservoir Port Engine 27 Cabin Stereo Speakers...

Страница 10: ...Starboard Visor Black or Blue 5 Weather Curtain ForwardVisor Black or Blue 6 250 CXLDTS Verado 4 Stroke w PowerAssisted Steering 7 225 DTS OptiMax Dual Engines 8 Graphics Striping Red or Blue 9 Folda...

Страница 11: ...VHF RadioAntenna 7 Radar Pedastal w Spotlight Option Only 8 Northstar 3300Autopilot 9 Additional 6000i Display 10 Spotlight Control Pad 11 Trim Tab Control w Indicators 12 MP3 Player receptacle 13 60...

Страница 12: ...Manual Entertainment Package Notable Options Con t 1 HeadAccess Door Mid Berth 5 Cruising Package 1 Mid Berth Privacy Curtain 2 15 Flat Screen LCDTelevision 3 DVDPlayer 4 Single Burner Electric Stove...

Страница 13: ...compartment w Cruise Pkg 7 Anchor Rode Locker 8 Starboard cabin V Berth Storage 9 Under Gunwale Rod Racks Port Starboard 10 Fishbox Port Starboard 11 Battery Storage Access 12 Oil Storage Access 13 Do...

Страница 14: ...d and resealed every other year NOTICE If the through hull fittings need to be replaced it is recommended that an authorized Boston Whaler dealer perform this type of repair Through hull fit tings tha...

Страница 15: ...g loading unload ing or when the boat is at rest NEVER oper ate the engine while loading or unloading swimmers divers from the swim platform ladder Be aware of your footing while the boat is underway...

Страница 16: ...o 7 8 9 10 WARNING co co co co co co co co co co co co co co co co co co co co co co co co co co co co NW 205 05 Carbon monoxide CO can cause brain damage or death Carbon monoxide can be present in th...

Страница 17: ...power connection Unplug shore power before removing cover Will cause personal injury or death Carbon monoxide CO can cause brain damage or death Engine and generator exhaust contains odorless and col...

Страница 18: ...00 CAUTION MRP 1836858 AVOID INJURY BOAT MOVEMENT MAY CAUSE LID TO FALL KEEP HANDS AND FEET CLEAR OF EDGES WHEN HATCH IS OPEN CAUTION MRP 1743504 ENSURE PROPER DRAIN PLUG INSTALLATION REMOVAL OF FISHW...

Страница 19: ...Gal 284L The saddle tanks are located port and starboard amidship aft of the mid cabin and the auxilliary tank is located under the mid cabin floor The optional 15 Gal 56 8L Diesel fuel tank is lo ca...

Страница 20: ...uldbeinspectedatleastevery100 hours Check the hoses for cracks abrasions and dete riorationandthestrongsmellof fuelpriortostartingthe engine s If the hoses or fittings are damaged or worn replacethemw...

Страница 21: ...uminumFuelTank Center 10 Center Fuel Tank Sender 11 Fuel Cap Key Supplied 12 Integrated Fuel Tank Vent 13 Fuel Tank Sender optional 14 1 5 Fuel Hose optional 15 Fuel Tank Vent optional 16 15 Gal 56 8L...

Страница 22: ...arboard Fuel Tank Connection 1 2 3 4 5 6 7 8 9 10 Fuel Valves Diagram 305 Conquest Owner s Manual To port engine To starboard engine Port Fuel Valve The 305 Conquests fuel system can be monitored via...

Страница 23: ...t been ventilated outside an en closedarea Useextremecautionwhenfuelingyourboat fromasourceoutsidetheregularvenues e g marinas fuelservicestations Your boat has safety features that can be circumvente...

Страница 24: ...effect the ethanol blended fuel A condition called phase separation can occur if water is ExampleofPhaseSeparation 1 2 3 4 1 2 3 4 The use of improper gasoline or additives can damage your fuel syste...

Страница 25: ...resence of water in the fuel tank If any is found all water must be removed and the tank completely dried before refillingthetankwithanyfuelcontainingethanol STORAGE Long periods of storage and or non...

Страница 26: ...3 three standard battery boxes and 1 one can be added as an option BATTERYBOXLOCATION The 3 standard battery boxes are located in the forward sectionofthemachinerycompartment BatteryBox Release Strap...

Страница 27: ...ke the shore power generatorAC load and convert it to a 12Volt DC load The batteries charge can be read by theDCvoltgaugeonthecabinMainDistributionPanel MDP 305 Conquest Owner s Manual Your 305 Conque...

Страница 28: ...ed preferred position when boat is not in use STARBOARD ENGINE Normal position while engaging in normal engine opera tions To parallel batteries set both switches to the ALL po sition Return to normal...

Страница 29: ...andtobeusedbyservice technicians Boston Whaler does not recommend that you attempt to work on the electrical system yourself instead we suggest that you take it to an authorized Boston Whaler dealer f...

Страница 30: ...Section 4 Electrical System 28 305 Conquest Owner s Manual Battery Switch Panel HelmBreakerPanel Hardtop Switch Panel...

Страница 31: ...Section 4 Electrical System 305 Conquest Owner s Manual 29 Cabin Breaker Panel Generator Panel...

Страница 32: ...Section 4 Electrical System 30 305 Conquest Owner s Manual Hull Wiring Diagram...

Страница 33: ...8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 15 Accessory 1 Switch 16 Accessory 2 Switch 17 WindshieldVentSwitch 18 PortWiper Switch 19 StarboardWiper Switch 20 Smartcraft SystemView 21 AirTemperatureSe...

Страница 34: ...s Refrigerator operates on both DC AC Stereo Carbon Monoxide Detector TheDCelectricalsystemconsistsofthefollowingma jorcomponents MainDistributionPanel MDP Batteries starboard 1 2 engine start port en...

Страница 35: ...maged in any way through chafing against fixed ob jectsorvibration beforeattemptingtotightenanycon nection itisimportanttoturnallthebatteryswitchesto the OFF position UseONLYtheappropriatetoolfor thej...

Страница 36: ...ion disconnection the main breakers should be in the OFF position WARNING Do not attempt to use more than two high amperage appliances at the same time as overloading of the circuitry may result causi...

Страница 37: ...ur boat from the shore power sys tem Theisolationtransformerminimizestheelectrolytic corrosion caused by stray currents It will also protect theboatfrommissinggroundorreversepolaritycondi tions The is...

Страница 38: ...he AC MDP 7 Analog Fuel Gauge Generator 8 Helm Breaker Panel located on wall below the steering wheel a1 5 amp Horn Breaker a2 5 amp Nav Anch Breaker a3 20 amp Trim Tabs Breaker b1 10 amp 12V Helm Rec...

Страница 39: ...e Page Directory Symbol 8 Engine RPM Indicator 9 Favorites Directory 10 Navigation FuelDirectory 11 PropulsionDirectory 12 SettingsDirectory 13 SystemDirectory 14 VesselDirectory Note To get the most...

Страница 40: ...Itistheresponsibilityoftheowner operator to ensure that the navigation lights are in good workingorderandthattheproperlightingisshown Navigation Lighting NOTICE Off Navigation Lights Anchor Lights Th...

Страница 41: ...ase is important refer to the wood location diagram for areas on the gunwales that are specifically designed for with standing the stress generated by a downrigger There are a variety of downrigger mo...

Страница 42: ...iton PushtheTESTbutton theapplianceshould shut OFF If it does the circuit was interrupted and it is workingproperly PushtheRESETbuttontoreturnthe power to the outlet If the power to the appliance was...

Страница 43: ...he float switch Each pump discharges wateroverboardviaathru hullfitting MAINTENANCE Thebilgepumpisacompletelysealedunitandmainte nance is very simple but it will require you to check aroundthefloatswi...

Страница 44: ...er located on the battery switch panel in the helm seat stand which protects the system fromelectricaloverload AnLEDlightonthebatteryswitchpanelindicatesthat thehighwaterpumpisactivated Anaudiblealarm...

Страница 45: ...ocatedundertheaccesshatchontheaft cockpitfloor Theflowcontrolvalveletsyouadjustthe flow of water into the livewell tank turning the handle clockwise90 willshutofftheflowofwater LIVEWELL SYSTEM The liv...

Страница 46: ...by a 3 5 GPM pump OPERATION The raw water pump has a seacock that needs to be set in the OPEN position before pump operation The seacock can be reached through the hatch located on the cockpit floor T...

Страница 47: ...galleyfaucetandheadcompartment shower sink and head The freshwater pump is located on the port sideofthemachineryaccesscompartment 305 Conquest FreshwaterTank Diagram FRESHWATERSHOWER The freshwater s...

Страница 48: ...ing the drain valve to flush the tank Water Heater Freshwater System con t COLD HOTWATER The freshwater tank of your boat is capable of supply ingcoldwatertotheheadcompartment galleyandbait prep stati...

Страница 49: ...leaksaroundthewaterheater call your dealer Manually operate the pressure relief valve at least once a year This must be done when the water in the storage tank is cool The system must be flushedsevera...

Страница 50: ...this is permissible if possible employ the use of a shore side discharge NOTICE HEAD SYSTEM Your 305 Conquest has a head com partment located on the aft starboard side of the cabin It is fitted with...

Страница 51: ...AINTENANCE Afterlongperiodsofnon use themaceratorpumpmay notturnfreely Regularuseofthesystemwill Section 6 Water Waste System 305 Conquest Owner s Manual Standard Waste System Diagram 1 VacuFlush Toil...

Страница 52: ...esignedandoperatedtopreventthe over board discharge of sewage treated or untreated or any other waste derived from sewage The EPAstandards further state that this shall not be construed to prohibit th...

Страница 53: ...ngsystembeservicedonlybyanauthorizedtechnician 1 2 4 5 Section 7 Propulsion System 305 Conquest Owner s Manual STEERING Hydraulic Steering Information Your 305 Conquest is equipped with a teleflex hyd...

Страница 54: ...hile in motion Understanding your boat and its reactions at speed will make boating for you safer and more enjoyable CAUTION Shift controls into NEUTRAL before starting engine Shift only when engine i...

Страница 55: ...testheRPMoftheengine RegulatingtheRPMoftheenginewillcontrolthe speed of the boat Moving the lever forward engages theforwardgear Continuingtomovethelever forward will increase the forward speed of the...

Страница 56: ...ing to a lower pitch propeller will in crease acceleration and load pulling capability with a slightdecreaseintopendspeed Ifyouchoosetochange propellers thetypeshouldbediscussedwithyourBos tonWhaler d...

Страница 57: ...s located on the center part of your console above the throttle control Short momentary bursts of the rockers will achieveproperattitudeofthehull Thetrimtabswitchis marked bow up and bow down Usingthe...

Страница 58: ...oning Raw Water Pump Strainer 9 Seacock for inlet of cooling water 10 Condensation Drain Line to shower sump 11 Sea Water Discharge Line 12 5 Flexible Duct 13 SMXir Key Pad Display 13 Head Compartment...

Страница 59: ...care when handling storing and using fuels WARNING MOVING PARTS Can cause SEVERE INJURY or DEATH Operate the generator set only when all guards screens and covers are in place WARNING FIRE Can cause...

Страница 60: ...rinjector failure The generator draws fuel from its own tank located on the port aft side of the compartment The fuel system has its own filter and fuel level indicator The exhaust fromthegeneratorpas...

Страница 61: ...seconds at a time Allow for a 60 second cool down period between cranking attempts If the generator fails to start after the first attempt CLOSE the seacock to prevent water from get ting into the ge...

Страница 62: ...eplacement is neccessary the number can be found in the operation manual The fuel filter water separator has a manufac turersownersmanualthathasalltheinformationforre placementofitsfilterelement Theen...

Страница 63: ...quest has a USCG approved automatic firesupressionsystemthatisinstalledwiththegenerator option The automatic fire supression system is located onthestarboardwallofthemachineryaccesscompart ment Theaut...

Страница 64: ...oy Engine Shutdown Override System Gauge Location EngineShutdown OverrideSystemGauge AutomaticFireExtinguishingCylinder location 305 Conquest Owner s Manual Section 8 Getting to know your Boston Whale...

Страница 65: ...ULL Tiethiscordaroundtheendof theelectronicscabletorunitupfromthecabinordown throughthehardtop Thefiberglasshardtophasachan nelthat will allow rigging from the hardtop frame through the hardtop to the...

Страница 66: ...nerycompartment Thecord atthisendisapproximately6ft 1 82m Therigginghose is 2 inches in diameter This diameter will be important as the rigging tube gets more populated To allow for moreelectricalacce...

Страница 67: ...Thesterneyesshouldbeusedastiedownpoints whiletraileringtheboat Thebowandsterneyesshould NEVER be used for lifting Lifting with the bow and sterneyescancauseharmfulstressonthefiberglassand gel coat PO...

Страница 68: ...ou follow all recommendations set intheengineowner soperationsmanual Itwillgiveyou ascheduleofwhentheseimportantfunctionsneedtobe done ENGINES Protecting your engines vital moving parts from corro sio...

Страница 69: ...ng Metal trim and fittings will stay bright if coated with a good grade metal polish or paste wax after washing Stainless steel is strong and corrosion resistant but still requires maintenance to keep...

Страница 70: ...n be cleaned with a coarse towel or soft bristle brush The growthshouldbecleanedimmediatelyaftertheboathas been removed from the water If the growth is allowed todryitwillbethatmuchhardertoremove Ifth...

Страница 71: ...drop side curtains can be rolled and stowed in the cabin of the boat Be careful to not fold or crease the visor section Theforwardvisorcanberolledupandissecuredtothe forward section of the hardtop wit...

Страница 72: ...n proper working order If you have stubborn cleaning cases call your Boston Whaler dealer for proper cleaning procedures Do not use bleach or solvents to clean the canvas material Canvas Care Maintena...

Страница 73: ...rbeforeusingtheanchorwind lass Follow all recommendations and instructions re garding its proper use and care ANCHOR Lowering theAnchor Be sure that there is enough rope for the depth of water you wil...

Страница 74: ...ind lasssystemcheckedbyaqualifiedmarineelectrician The anchor windlass is located directly port of the an chor locker The anchor windlass gives you a mechani calmeansof raisingandloweringtheanchor OPE...

Страница 75: ...RemotePowerPlug 4 AnchorWindlass 5 AnchorWindlassHandle 6 AnchorWindlassStorage 7 AnchorWindlassOperationSwitch 8 AnchorWindlassBreaker 1 2 4 5 8 7 305 Conquest Owner s Manual Section 9 Anchoring Inf...

Страница 76: ...Section 10 Maintenance Log Notes Engine Hours Serviced by Maintenance Performed After the scheduled services are performed fill out the areas below Date Maintenance Record Notes 74...

Отзывы: