background image

WASP

TM 

Wireless Acceleration Sensor Puck Operations Manual  

- 1 -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING 

READ THIS MANUAL BEFORE OPERATING THIS DEVICE. 

 

MISE EN GARDE 

LISEZ LE MANUEL AVANT UTILISATER 

 

WARNING 

TO PREVENT EQUIPMENT FAILURE, AND/OR DAMAGE,  

AND/OR PERSONAL INJURY, REGULAR CALIBRATION  

AND INSPECTION OF THIS DEVICE IS REQUIRED. 

 

MISE EN GARDE 

POUR PR

ЀVENIR LE DOMMAGE À L’EQUIPMENT, ET/AU AUX 

PERSON, LA CÀLIBRATION ET L’INSPECTION REGULIER EST 

ŔEQUIS. 

 

Содержание WASP WASP2

Страница 1: ...A45 Test Report S N 45461472 R1 0 ISED ID 9648A EA45 2019 Celltech Labs Inc This document is not to be reproduced in whole or in part without the expressed written permission of Celltech Labs Inc Page 26 of 48 EXHIBIT 19A USER S MANUAL HOST 1 WASP2 See Attached ...

Страница 2: ...WASP WASP2 Wireless Acceleration Sensor Puck USER MANUAL VERSION 1 00 2018 12 04 ...

Страница 3: ...SP is a PATENT PENDING technology owned by BossPac Engineering Technology BossPac Engineering Technology 1450 28 Street NE Bay 8 Calgary Alberta Canada T2A 7W6 Phone 403 216 1226 Fax 403 216 5557 E Mail info bosspac com Visit our website for more information www bosspac com ...

Страница 4: ...DEVICE MISE EN GARDE LISEZ LE MANUEL AVANT UTILISATER WARNING TO PREVENT EQUIPMENT FAILURE AND OR DAMAGE AND OR PERSONAL INJURY REGULAR CALIBRATION AND INSPECTION OF THIS DEVICE IS REQUIRED MISE EN GARDE POUR PRЀVENIR LE DOMMAGE À L EQUIPMENT ET AU AUX PERSON LA CÀLIBRATION ET L INSPECTION REGULIER EST ŔEQUIS ...

Страница 5: ...MENT RISQUE D EXPLOSION LA SUBSTITUTION DECOMPOSANTS RENDRE CE MATÉRIEL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE 1 DIVISION 2 WARNING EXPLOSION HAZARD DO NOT REMOVE BATTERIES UNLESS AREA IS KNOWN TO BE NON HAZARDOUS AVERTISSEMENT RISQUE D EXPLOSION AFIN D ÉVITER TOUT RISQUE D EXPLOSION S ASSURER QUE L EMPLACEMENT EST DÉSIGNÉ NON DANGEREUX AVANT CHANGER LA BATTERIE ...

Страница 6: ...ensor Pucks 4 2 1 1 Battery Installation 4 2 1 2 Cap and Gasket Installation 5 2 1 3 WASP LED Error Indicator 6 2 3 Placement Of The WASP Pucks 6 2 3 1 WASP Mounting 6 2 3 2 WASP Sensor Placement 6 2 3 3 Mounting Surface Preparation 6 2 4 Optional Thermal Calibration Of WASP s 6 3 Troubleshooting WASP LED Flash Codes 7 3 1 LED Flash Codes 7 3 2 What To Do When An Error Is Reported 8 3 3 Contact In...

Страница 7: ...t and mounting screws to secure the top cap The BossPac WASP and WASP2 sensor pucks use an attached magnet base for mounting to equipment Optional mounting methods are available stud mount pipe clamp epoxy 2 2 Assembling Of Wireless Sensor Pucks 2 1 1 Battery Installation Each sensor puck is shipped with a WASP2 Battery Cap Assembly containing a battery circuit board The Battery Cap Assembly conta...

Страница 8: ...the WASP device performs a power on self test POST The sensor is now detectable by any BossPac NEST receiver within the working radius Figure 1 Install WASPTM Battery Board 2 1 2 Gasket and Cap Installation Each sensor comes with a gasket Place gasket onto battery cap or housing prior to connecting battery The gasket is required to maintain an IP54 rating between the housing and the top cap batter...

Страница 9: ...tic base is screwed securely to the stud on the bottom of the WASP Check the top cap screws are tightened to a maximum of 15 ft lb or 1 7 N m In less than ideal conditions a small amount of SILICON HEAT TRANSFER COMPOUND may be used to facilitate a more efficient heat transfer from the mounting surface into the sensor It is necessary to only cover the stud part of the sensor This requires only a s...

Страница 10: ...erations Manual 7 3 Troubleshooting WASP LED Flash Codes 3 1 LED Flash Codes An LED indicator light is mounted on the board located in the sensor housing The following table contains a brief description of all flash codes reported by the device ...

Страница 11: ...ace the battery board Temperature Sensor Failure 3 Flash If the device is not powering up in extreme temperatures this may be indicative of an electrical fault with the RTD Recommend replacing the WASP unit Radio Failure 4 Flash Much like an accelerometer failure this is indicative of an electrical failure The problem is much more severe in this instance as the device cannot communicate Recommend ...

Страница 12: ...ference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d e...

Отзывы: