WASP
TM
Wireless Acceleration Sensor Puck Operations Manual
- 5 -
To turn on and activate each sensor puck you must carefully attach the battery cap
assembly to the sensor unit. Place gasket (see section 2.1.2) and plug the connector on
the battery assembly into the corresponding socket on the sensor puck housing. Figure 1.
It is important the battery board is properly mated to the WASP
™ Sensor connector. An
incorrectly mated connection may result in intermittent/inconsistent power, or complete
loss of power to the Sensor. A loose connection may also cause damage to the connector
pins as well.
Once the connection is made the WASP
™ device performs a power-on self test (POST).
The sensor is now detectable by any BossPac NEST receiver within the working radius.
Figure 1: Install WASP
TM
Battery Board
2.1.2 Gasket and Cap Installation
Each sensor comes with a gasket. Place gasket onto battery cap or housing prior to
connecting battery. The gasket is required to maintain an IP54 rating between the housing
and the top cap battery assembly.
There is no specific orientation required for the top cap, however it is important the power
connector wire maintains a reasonable bend radius and is not pinched during assembly.
A simple ¼ turn of the cap may be all is needed to ensure the wire lays securely in the
housing. The top cap is secured/retained by four 8-32 stainless steel screws.
WARNING
– DO NOT REMOVE THE FOUR SCREWS ON THE BOTTOM OF THE DEVICE