Press 'SELECT' to exit setting of 'dt' value.
If 'dt' is greater than '00', the display will skip the 'tt'
option and prompt for the 'Sr' setting.
Press 'SELECT' to exit setting of 'Sr' value. Display will
prompt for SA setting.
Press 'SELECT' to return to normal operating mode.
Count value is displayed
When using a single gate switch (DIP SW2 On) to enable
the batch start, option 'SA' allows the choice of swit-
ching witch either of the following:
Press 'SELECT' to exit setting of 'tt' value. Display will
prompt for Sr setting.
Optional 'dt' and 'tt' Cycle Time Alarms. other misc options
Two optional alarms are provided to alert the operator if too much time is being taken to run the screws
into the assembly. The 'dt' Standby Time Alarm can be set in 1 second intervals. It is the allowable time to
run each screw cycle. If, during the batch, the screwdriver remains idle for a time exceeding the 'dt' value,
an audible alarm will sound and the display will flash 'dt' until the driver is triggered for the next cycle.
(Note: depending on other program settings. the operator may need to press 'S' to continue driving
screws if 'dt' is flashing in the display.)
The 'tt' Total Batch Time Alarm can be set in 1 minute intervals. If the batch is not completed within the
'tt' time setting, an alarm will sound and the display will flash 'tt' until the operator runs the driver and
completes the batch. Only one of the two optional alarms can be selected for use.
Adjust value
UP / DOWN
Press until 'dt'
or 'tt' displays.
Release to
view value
Adjust value
UP / DOWN
Toggle value
Toggle value
The controller also has a selectable slow start option. This option can be helpful in engaging screw threads
properly to avoid cross threading. The slow start is intended for initiating the fastener rundown only – the
slow start time must be limited so that the tool switches to full speed before the fastener completed its
rundown.
The 'Sr' value is valid when the controller is set to run
multiple sequences (DIP SW6 On) and the batch enable
input (DIP SW2 On, or DIP SW2 & 4 On) is being used
to confirm the batch start via an external switch. If 'Sr'
is set to the default value of 'n' (no), the controller will
require an external enable input at the beginning of the
first sequence U1 only.
If 'Sr' is set to 'y' (yes), the controller will require an
enable input at the beginning of each sequence (eg. U1,
U2 and U3 will all require an enable if 3 sequences are
running sequentially).
If 'dt' = 00, the display will prompt for input of a 'tt' value.
Hi =
use a normally closed contact, momentarily open to enable
Lo =
use a normally open contact, momentarily close to enable