19
BoSS X-Series
User guide
In the unlikely event of a power failure of the BoSS X-Series machine
the platform can be lowered manually by use of the following
procedure:
STEP 1
Turn the finger screw on the emergency descent valve
anticlockwise until it will not turn any further, as shown in Figure 1 below.
STEP 2
Pull the red handle under the step up to the platform towards
you until the platform has fully lowered, as shown in Figure 2 below.
If for any reason, you need to stop the emergency descent at any
time, release the handle and the platform will stop descending.
To continue the descent pull the red handle again.
Figure 1
Figure 2
WARNING
Always ensure that someone at ground level i.e. other than the
operator, is trained to perform this procedure.
In the unlikely event that the motor will not stop running, even after
both emergency stop buttons have been depressed, open the drawer
in the chassis and using the red strap remove the 100A fuse and close
the drawer before undertaking the emergency lowering procedure
above. DO NOT reuse the machine until it has been inspected, and if
necessary repaired, by a competent engineer.
4.8
Emergency lowering
A battery charge level indicator is fitted to the BoSS X-Series machine.
When the machine is fully charged all segments on the indicator will
be illuminated red, as shown in Figure 1 below. When only the first
segment, on the left of the indicator is illuminated red and flashing, as
shown in Figure 2 below, it is time to put the machine on charge.
4.9
Battery charging
Figure 1
Figure 2
BoSS_XSeries_Userguide_Rev C 0519_English.indd 19
08/05/2019 12:20