BoSS X-Series machines are fitted with a low battery protection
system. If the battery level falls below 10%, then the platform will not
raise but can still descend. The BoSS X-Series machine is fitted with
an integral battery charger. To charge the battery, follow these steps:
STEP 1
Depress the emergency stop button on the handset
controller and remove the key.
STEP 2
Turn the cover to expose the battery charging cable
connection point, as shown in Figure 1 below.
Figure 1
Figure 2
STEP 3
Connect either the mains power or 110V transformer
charging cable to the BoSS X-Series machine battery charging
cable connection point, as shown in Figure 2 above. Both of these
cables can be found in the tool box which is mounted on the platform
guardrail.
STEP 4
Plug the other end of the charging cable into either a mains
240V or transformer 110V power supply.
STEP 5
While the battery is charging to 80% of its capacity the
second LED from the left on the indicator will be flashing green as
shown in Figure 1 below. When the charging of the final 20% is
underway the third LED from the left will be flashing green as shown
in Figure 2 below.
STEP 6
When the battery is fully charged, all four lights will
illuminate, after approximately ten hours.
WARNING
BoSS X-Series machines must be charged where the ambient
temperature is between 0 and 45ºC.