309003
8.10 Contacting Boss Industries Inc.
Phone: (800) 635-6587 (USA)
Phone: (219) 324-7776 (Outside USA)
Fax: (877) 254-4249 (USA)
Email: [email protected]
Website: http://www.bossair.com
When calling for technical support, have the following information available:
Machine Serial Number
Description of the problem
8.8 Coalescer Plugging
If the coalescer element has to be replaced frequently because it is plugging up, it is an indication that foreign
material may be entering the compressor inlet or the compressor oil is breaking down.
Compressor oil can break down prematurely for a number of reasons.
I.
Extreme operating temperature
II. Negligence in draining condensate from oil sump
III. Using the improper type of oil
IV. Dirty oil.
The complete inlet system should be checked for leaks.
Troubleshooting
8.9 High Compressor Discharge Temperature
I.
Check compressor oil level. Add oil if required (see section for oil specifications).
II. Check electric fan and switch.
III. Clean outside of oil cooler.
IV. Clean oil system (cooler) internally.
V. Plugged compressor oil filter. Change element.
VI. Plugged oil return line, clean orifice and check valve.
Содержание Bullet 2
Страница 2: ...2 309003...
Страница 26: ...26 309003...
Страница 27: ...27 309003 WARRANTY SECTION...
Страница 33: ...33 309003 PARTS AND ILLUSTRATION SECTION...
Страница 37: ...37 309003 Engine System 5 5 6 4 1 2 10 9 8 7 3 10 2 Engine System continued...
Страница 41: ...41 309003 Cooler System 6 3 10 2 7 5 9 1 8 4 10 4 Cooler System continued...
Страница 47: ...47 309003 Coalescer System 16 8 8 2 5 10 4 3 4 1 11 15 14 13 7 9 6 18 17 30 10 7 Coalescer System continued...
Страница 48: ...48 309003 Wiring Diagram 10 8 Wiring Diagram...
Страница 49: ...49 309003 System Schematic 10 9 System Schematic...