Boschetti Industrie Meccaniche srl
13
IT
Ver. 01/2019
Pilot’s injector replacement
This operation must be carried out only by a qualified staff. You have to follows these directions:
- dismount the burner’s cover and the burner's protection mask;
- loose the fitting of the valve-pilot's gas tube;
- take away the injector by slipping off the valve-pilot's gas tube;
- set the new injector in the pilot burner and fix correctly the connection.
Application/removal of the mask for burner tube
For the transformation from natural gas to LPG must be applied the mask for burner tube. This operation must be
carried out only by a qualified staff. You have to follows these directions:
- dismount the burner’s cover and the burner's protection mask;
- unscrew the burner fixing screw;
- apply the mask for burner tube on the burner support bracket as indicated in picture 11;
- fix with the burner fixing screw.
Note: for the transformation from LPG to natural gas the mask for burner tube must be removed.
Picture 10
Pilot’s injector replacement
Pilot’s injector
Valve-pilot's gas tube
Fitting
Picture 11
Application of the mask for burner tube
Mask for burner tube
Burner fixing screw
Burner's
protection mask
Burner’s cover
Burner's
protection mask
Burner’s cover