2 INSTALLATION
2.1 Basic
installation
Dryers shall be installed according to national and local codes.
2.2 Exhaust
vents
2.2.1 Locating exhaust vent
Vent is factory installed to the rear of dryers. Rear factory vent can be
changed to the bottom or right side using kits (sales accessories).
2.2.2 Installing
vent
ducts
For best drying, use shortest possible duct length and fewest # of
elbows.
Use the table below when selecting ducting.
# 90º Turns /
Maximum Length
Elbows
Rigid Duct
Flexible Duct
0
20 m
14 m
1
17 m
11 m
2
14.5 m
9 m
3
12 m
7 m
4
9 m
5 m
2.3
Feet (leveling legs)
Using a level front to back and side to side, adjust feet (leveling legs)
until dryer is level. When moving dryers, screw in feet completely
before moving dryers to avoid damage.
To adjust feet (leveling
legs), rotate left to right to
lower dryer.
702_58300000143767_ara_en_a