background image

5

6720819898 C  11/2017

WARNING: Some parts of your appliance, especially 

the external surfaces, will be hot to touch when in 

operation. Due care should be taken to prevent 

burns. Keep children away from the appliance during 

operation.

1

2

3

4

5

6

7

8

9

10

11

12 13

14

15

16

USER INFORMATION

ADDITIONAL INFORMATION BEFORE INSTALLING 

YOUR MULTIFUEL STOVE

•  Once you determine the room in which your multifuel stove will be 

installed, install a carbon monoxide alarm in the same room. This 

alarm should be installed 1-3m from the stove. When mounted 

on  a  wall  it  must  be  at  least  150mm  below  the  ceiling.  When 

mounted to the ceiling it must be 300mm away from all walls.

•  All  local  regulations,  including  those  referring  to  national  and 

European  standards  need  to  be  complied  with  when  installing 

the appliance.

•  Any air inlet grilles are to be positioned so they are not liable to 

blockage.

•  Do  not  use  your  appliance  as  an  incinerator.  Only  burn  well 

seasoned wood or Defra exempt smokeless fuel.

•  A  minimum  of  annual  maintenance  is  necessary  to  be  sure 

your  appliance  is  running  optimally.  All  maintenance  must  be 

performed by a competent engineer or Chimney Sweep. Access 

should be provided for regular cleaning of the appliance, flue gas 

connector and chimney flue.

•  Do not operate your appliance with the fueling door open. Only 

operate with the fueling door open during ignition, refueling and 

removal of residue material to prevent fume spillage. Operating 

with the fueling door open can cause over-firing of your appliance. 

Operation with the door open can cause excess smoke. 

•  This appliance is NOT suitable for installation in a shared flue 

system.

•  This appliance is suitable and has been tested for intermittent 

operation.

•  There must be no unauthorized modification of the appliance.

THE CLEAN AIR ACT 1993 AND SMOKE CONTROL 

AREAS

Under  the  Clean Air Act  local  authorities  may  declare  the  whole 

or part of the district of the authority to be a smoke control area. It 

is an offence to emit smoke from a chimney of a building, from a 

furnace or from any fixed boiler if located in a designated smoke 

control area. It is also an offence to acquire an “unauthorized fuel” 

for use within a smoke control area unless it is used in an “exempt” 

appliance (“exempted” from the controls which generally apply in 

the smoke control area).

In England, appliances are exempted by publication on a list by the 

Secretary of State in accordance with changes made to sections 20 

and 21 of the Clean Air Act 1993 by section 15 of the Deregulation 

Act  2015.  Similarly  in  Scotland,  appliances  are  exempted  by 

publication on a list by Scottish Ministers under section 50 of the 

Regulatory Reform (Scotland) Act 2014.

In Wales and Northern Ireland, these are authorised by regulations 

made by Welsh Ministers and by the Department of the Environment 

respectively.

The Hanbury 4 has been recommended as suitable for use in smoke 

control areas when burning wood logs or Defra exempt smokeless 

fuel, when operated in accordance with these instructions and when 

fitted with a modification that prevents closure of the Secondary Air 

control.

The Hanbury 5 has been recommended as suitable for use in smoke 

control areas when burning wood logs or Defra exempt smokeless 

fuel, when operated in accordance with these instructions and when 

fitted with a modification that prevents closure of the Secondary Air 

control.

The Hanbury 8 has been recommended as suitable for use in smoke 

control areas when burning wood logs or Defra exempt smokeless 

fuel, when operated in accordance with these instructions and when 

fitted with a modification that prevents closure of the Secondary Air 

control.

Further information on the requirements of the Clean Air Act can be 

found here : https://www.gov.uk/smoke-control-area-rules

Your local authority is responsible for implementing the Clean Air Act 

1993 including designation and supervision of smoke control areas 

and you can contact them for details of Clean Air Act requirements.

PERMANENT AIR VENT

All stoves requires an adequate air supply in order to operate safely 

and efficiently. In accordance with current Building Regulations the 

installer may have fitted a permanent air supply vent into the room 

in which the stove is installed to provide combustion air. This air 

vent should not under any circumstances be shut off or sealed.

SETTING UP YOUR STOVE

Make sure that the room in which the stove is set up has at least 

one door or window into the outside or is directly adjacent to such a 

room. Other fireplaces or exhaust fans must not be operated in the 

same room as this stove.

STOVES GUARANTEE - REGISTRATION

Please visit the website: worcester-bosch.co.uk/guarantee so that 

you can register your stove online or via the Worcester Guarantee 

App. Alternatively, if you wish to register your Worcester Greenstyle 

Stove Guarantee via telephone please call 03301 232 552.

Required safety distances (minimum clearances to combustible 

materials.
Hanbury 4

Hanbury 5

Hanbury 8

A > 1200mm 

(toward the front of 

the stove)

A > 1200mm 

(toward the front of 

the stove)

A > 1200mm 

(toward the front of 

the stove)

B > 600mm (to the 

side)

B > 600mm (to the 

side)

B > 700mm (to the 

side) 

C > 750mm (to the 

back)

C > 725mm (to the 

back)

C > 700mm (to the 

back)

Содержание Worcester Greenstyle Hanbury 4

Страница 1: ...Installation servicing and user instructions Multifuel Stove Defra Exempt Smokeless Fuel Greenstyle Hanbury 4 5 8 ...

Страница 2: ...TO SYMBOLS AND SAFETY INSTRUCTIONS 3 2 APPLIANCE INFORMATION 4 3 USER INFORMATION 4 5 4 INSTALLATION 6 20 5 COMMISSIONING 21 6 USER INSTRUCTION 21 25 7 SERVICE AND SPARES 26 31 8 NOTES 32 33 9 COMMISSIONING CHECKLIST 34 10 SERVICE RECORD 35 ...

Страница 3: ...WORDS AT THE START OF A WARNING INDICATE THE TYPE AND SERIOUSNESS OF THE ENSUING RISK IF MEASURES TO PREVENT THE RISK ARE NOT TAKEN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Symbol Meaning a numbered step in an action sequence a step in an action sequence a reference to a related part in the document or to other related documents a reference number to identify o...

Страница 4: ...he operation of the stove APPLIANCE INFORMATION USER INFORMATION TECHNICAL DATA Hanbury 4 Hanbury 5 Hanbury 8 Height To Top Of Stove 546mm 583mm 621mm Height To Top Of Spigot 585mm 622mm 664mm Width 394mm 419mm 436mm Depth 325mm 341mm 440mm Weight 63kg 77kg 99kg Flue Pipe 127mm 127mm 127mm Nominal Thermal Output Wood 4 2kW 5 0kW 7 7kW Nominal Thermal Output Smokeless 4 3kW 5 0kW 7 5kW Fluegas Mass...

Страница 5: ...eregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Wales and Northern Ireland these are authorised by regulations made by Welsh Ministers and by the Department of the Environment respectively The Hanbury 4 has been recommended as suitable for use in smoke control areas when...

Страница 6: ...Remove the remaining top panel 3 Remove the baffle fastener card legs ash pan log guard glove and flue collar from inside the firebox of the stove FASTENER CARD INSTALLATION Contents List Qty Item 1 Baffle 1 Fastener Card 4 Legs 1 Ash Pan 1 Log Guard 1 Glove 1 Flue Collar 1 Ash PanTool ...

Страница 7: ...rder of the above steps Note Clean the baffle regularly to ensure safe and efficient operation of the stove To locate the bottom of the baffle there is a H4 H5 or H8 depending on the model purchased cut into the bottom of the baffle along with two arrows When reinstalling the baffle be careful not to install the baffle upside down When correctly installed the H4 H5 or H8 cutout will rest on the re...

Страница 8: ...lign the leg with the stove 2 Insert the provided A bolt and C washer 3 Repeat for the remaining three legs LEG LEVELERS Insert four A bolts into the bottom of the stove leg and adjust as needed for leveling REMOVING THE ASHPAN INSTALLATION A C A A ...

Страница 9: ... two large notches The two large notches must face to the front of the stove or the grate will not correctly install 3 Install the left and right brick liners flip left brick liner to fit 4 Install the log retainer by sliding down into the slots located at the front of the door INSTALLATION Small Rear Notch Large Front Notc Small Rear Notch Large Front Notch ...

Страница 10: ... Insert the rear brick liner into the unit through the front door 2 Next insert the right and left brick liners by sliding them down into the slots provided 3 Insert the grate 4 Slide the log retainer down into the slots located at the front of the door INSTALLATION ...

Страница 11: ...rom the flue cover plate 2 Reach in through the front door of the stove and remove the three B bolts and C washers that are holding on the flue collar 3 Attach the flue collar to the rear of the unit with three B bolts and C washers 4 Attach the flue cover plate to the top of the stove with the three bolts and washers you previously removed B C B C B C B C ...

Страница 12: ...e multifuel stove must not be connected to a hot air distribution system since an excessive accumulation of heat may occur Your stove has been tested to applicable international standards and therefore As a general rule it is always advisable for a stove to be installed upon a constructional hearth but in certain instances when only being used to burn wood and not in a recess it may be installed u...

Страница 13: ... weight of the appliance and its chimney if the chimney is not independently supported Appliances should stand wholly above hearths made of non combustible board sheet material or tiles at least 12mm thick if the appliance is not to stand in an appliance recess or already on a constructional hearth in accordance with the paragraph below CONSTRUCTIONAL HEARTH Constructional hearths should have plan...

Страница 14: ...a clearance of 50mm to non combustible material If this reduced clearance installation is performed it is critical to respect the clearances to any combustible materials in the proximity of this installation Combustible materials could include but not be limited to paint or a finish material on the non combustible materials Combustible materials would include these materials coming in contact with...

Страница 15: ...ust be short and straight Any installation with a horizontal run of chimney pipe must conform to Document J To ensure a good draught the total length of the connecting flue pipe should never exceed 2 m Installation of a draught damper is not recommended Indeed with a controlled combustion multifuel stove the draught is regulated upon intake of the combustion air in the stove and not at the exhaust...

Страница 16: ...ith access cover To chimney connection as detailed in building regulations Support as per chimney manufacture instructions 600mm min 1000mm max unsupported Elbow with access cover To chimney connection as detailed in building regulations Support as per chimney manufacture instructions TOP FLUE REAR FLUE INSTALLATION ...

Страница 17: ...e separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions If it is found that there is excessive draught in the chimney then a draught stabiliser should be fitted Fitting of a draught stabilizer will affect the requirement for the permanent air supply into the room in which the stove is fitted in accordance with Approved Document J ...

Страница 18: ...uilding external surface such as its roof tiles or external walls 3 The clearances given for A or B as appropriate will also apply 150mm max Datum for vertical measurements The datum for vertical measurements is the point of discharge of the flue or 150mm above the insulation whichever is the lower Datum for horizontal measurements Adjacent building Regulated building A B C D weather surface Notes...

Страница 19: ...e metal chimneys should be kept a suitable distance away from combustible materials Ways of meeting the requirements for chimneys designated to BS EN 1856 1 2003 comprise Locating the chimney not less than distance xx from combustible material where xx is defined in BS EN 1856 1 2003 as shown in the diagram below Where a chimney passes through a cupboard storage space or roof space providing a gua...

Страница 20: ...ither a extend beyond the fluepipe by at least 1 5 x D or b make any path betweeb fluepipes and combustible material at least 3 x D long Air space of at least 12mm between non combustible shield and combustible material Plan with shield Indicates combustible material Protecting combustible material from uninsulated fluepipes for solid fuel appliances AIR REQUIREMENTS AND ASSESSING AIR PERMEABILITY...

Страница 21: ...d be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons These instructions together with those in the instruction booklet cover the basic principles to ensure the satisfactory installation of the stove although detail may need slight modification to suit particular local site conditions In all cases the installation must comply with cu...

Страница 22: ...soline or other flammable liquids should never be used to light the fire Before igniting the paper and kindling wood it is recommended that you warm up the chimney This is done in order to avoid back draught problems often due to negative pressure in the house If such is the case open a window slightly near the stove and twist together a few sheets of newspaper into a torch Light up this paper tor...

Страница 23: ...ween 123 C and 270 C Below these temperatures the build up of creosote is promoted Above 300 C heat is wasted since a too large quantity is lost into the atmosphere REFUELING If there is insufficient burning material in the fire bed to light a new wood log excessive smoke emission can occur Refueling must be carried out onto a sufficient quality of glowing embers and ash approximately 25 mm deep E...

Страница 24: ...the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wood used was too damp or has dried in poor conditions These problems can be ignition problems creosote build up causing chimney fires low energy yield blackened stove windows incomplete log combustion Smaller pieces of wood will dry faster All logs exceeding 152mm in diameter should be split ...

Страница 25: ... eight 8 screws and washers Remove glass and dispose of properly When replacing the glass you should change the glass gasket to make sure you keep it sealed To help with future removal of screws before reinstalling the glass clean the screws with light oil and coat with a high temperature anti seize grease Fit the new glass sealing rope onto the glass clamp Carefully wrap glass sealing rope around...

Страница 26: ...26 6720819898 C 11 2017 HANBURY 4 SERVICE AND SPARES 3 2 1 4 6 8 12 13 14 9 11 12 10 5 5 7 15 19 20 21 22 16 17 18 ...

Страница 27: ... 296 Multifuel Grate Frame 4kW 1 7 8 716 118 303 Leg 4kW 1 8 8 716 118 295 Ash Pan 4kW 5kW 1 9 8 716 118 289 Log Retainer 4kW 1 10 8 716 118 304 Air Slider Bottom Primary 4kW 1 11 8 716 118 297 Tool Ash Pan 1 12 8 716 118 235 Small Knob 1 13 8 716 118 287 Top Primary Air Slider 4kW 1 14 8 716 118 288 Air Wash Box 4kW 1 15 8 716 118 298 Door Assembly 4kW 1 16 8 716 118 302 Door Handle Knob Kit 1 17...

Страница 28: ...28 6720819898 C 11 2017 HANBURY 5 SERVICE AND SPARES 14 13 12 13 9 8 11 10 7 3 5 6 4 23 15 1 2 13 12 1 21 23 16 20 18 22 19 17 ...

Страница 29: ... Pan 1 13 8 716 118 235 Small Knob 1 14 8 716 118 308 Air Slider Top Primary 5kW 1 15 8 716 118 309 Air Wash Box 5kW 1 16 8 716 118 316 Door Assembly 5kW 1 17 8 716 118 302 Door Handle Knob Kit 1 18 8 716 118 301 Door Handle Kit 1 19 8 716 118 307 Door Pin Kit 2 20 8 716 118 346 Outer Door 5kW 1 21 8 716 118 319 Main Door Glass 5kW 1 22 8 716 118 300 Glass Clamp 4kW 5kW 2 23 8 716 118 320 Door Rop...

Страница 30: ...30 6720819898 C 11 2017 HANBURY 8 14 13 12 13 9 8 11 10 7 3 5 6 4 23 15 1 2 13 12 1 21 23 16 20 18 22 19 17 SERVICE AND SPARES ...

Страница 31: ...sh Pan 1 13 8 716 118 235 Small Knob 1 14 8 716 118 321 Top Primary Air Slider 8kW 1 15 8 716 118 322 Air Wash Box 8kW 1 16 8 716 118 330 Door Assembly 8kW 1 17 8 716 118 302 Door Handle Knob Kit 1 18 8 716 118 301 Door Handle Kit 1 19 8 716 118 307 Door Pin Kit 2 20 8 716 118 347 Door 8KW 1 21 8 716 118 334 Main Door Glass 8kW 1 22 8 716 118 331 Glass Clamp 8kW 2 23 8 716 118 335 Door Rope Seal 8...

Страница 32: ...32 6720819898 C 11 2017 NOTES ...

Страница 33: ...33 6720819898 C 11 2017 NOTES ...

Страница 34: ...equirements oved Document J Appendix E Confirm you have commissioned and tested the appliance and assoc As the competent person responsible for the work described above I confirm that the appliance and associated work has been installed in accordance with and compl proved Documents J G L as applicable Signed __________________________________Print Name ________________________________Date __________...

Страница 35: ... ____________________________________ Service 04 Date_________________________ Engineer Name _____________________________________ Company___________________________________________ Telephone No ______________________________________ Stove Inspected Chimney Swept Items Replaced ____________________________________ Service 05 Date_________________________ Engineer Name _____________________________...

Страница 36: ...3 2445 S PAR ES 0330 123 9779 LITE R ATUR E 0330 123 9119 TR AINING 0330 123 0166 S ALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Worcester Bosch Group is a brand name of Bosch Thermotechnology Ltd www worcester bosch co uk 6 720 819 898 C 11 2017 ...

Отзывы: