Appliance information
Greenstar Danesmoor Utility
ErP+
and Utility System
ErP+
- 6 720 821 720 (2018/04)
6
3
Appliance information
3.1
General information
Standard package:
A - Floor standing oil fired condensing boiler
B - Literature pack:
• Greenstar Danesmoor Installation, Commissioning and Servicing
instruction manual
• User Instructions
• Fascia information card
• Guarantee registration card
C - BSP plug, one inch (Regular only)
D - ErP label
E - Flue damper
3.2
Technical data
6720821720 - 05.1W
o
D
600mm
370mm
855mm
B
C
A
E
Description
Units
12/18 18/25 25/32
Central heating
Central heat output (max)
kW
18
25
32
Primary water capacity (total)
litres
20
21
22
Maximum static head
metres
30
30
30
Minimum static head
metres
1
1
1
Water side resistance (20°C
difference)
mbar
20
30
56
Maximum available pump head
(20°C difference) Utility System
mH
2
O
5.2
4.3
4.1
Maximum permissible sealed
system operating pressure in
accordance with WRAS
guidelines
bar
2.5
2.5
2.5
Flue
Exit flue gas mass flow
kg/hr
29
40
51
Pipework connections
Fuel line (compression)
mm
10
10
10
Flow Utility
BSP
1”
1”
1”
Flow Utility System
mm
22
22
28
Utility flow and optional vent/air
vent
BSP
1
1
1
Return
mm
22
22
28
Condensate (Polypropylene)
mm
21.5
21.5
21.5
PRV outlet - Utility System
mm
15
15
15
Electrical
Electrical power supply voltage ac ..V
230
230
230
Frequency
Hz
50
50
50
Thermostats
Boiler flow temperature range
(cut in/cut out)
°C
55/81 55/81 55/81
Control thermostat differential
°C
5
5
5
Boiler high limit thermostat set
point
°C
95
95
95
Boiler manual reset overheat
thermostat set point
°C
105
105
105
Flue manual reset overheat
thermostat set point
°C
110
110
110
General data
Maximum hearth temperature
°C
<100
<100
<100
SEDBUK 2009
%
91.1
90.9
90.7
SEDBUK 2005
%
93.2
93.0
92.8
Appliance protection rating
IP
20
20
20
Weight (excluding packaging)
Utility Regular
kg
104
108
115
Weight (excluding packaging)
Utility System
kg
112
112
122