3.4 Dryer
heater
3.4.1 Design
As the new heating duct contains 2x 920 W heating elements, the
drying process can be implemented in 2 stages with a total of 1840 W.
To reduce heat losses, the heating duct is thermally separated from
the fan by a seal.
1
RD1
Î
CNM3
2
RD2
Î
CNM1
3
RD1
Î
THS/RD2
4
RD2
Î
THS/RD1
3.4.2 Resistance
measurement:
Connections
Resistance in ohm
1–2
:
104–124
1–3
:
52–62
1–4
:
52–62
2–3
:
52–62
2–4
:
52–62
3–4
:
0
3.4.3 Function
The temperature is controlled by an
NTC
at the inlet to the gasket.
Cottons/coloureds: 87 °C–90 °C
Easy care:
67 °C–70 °C
Safety temperature: 105 °C
Î
error message!
In addition a resettable safety temperature controller monitors the
maximum permitted temperature. (150 °C)
During the
warm spin cycle
(54 UpM) only one heating element is
actuated!
815_58300000146136_ara_en_b.doc – 12.04.10
Seite 10 von 32