1 689 975 224
2013-11-06
|
Robert Bosch GmbH
36 | VLE 21xx | EEPROM
en
5.3
Potentiometers
5.3.1
Wiring of potentiometers
Contents
Wiring of potentiometers
Applicability
VLE 2130, VLE 2130 F, VLE 2130 E,
VLE 2130 EL, VLE 2140 EL
The potentiometers P1 and P2 are not marked on the
lifting platform. The position of the components is as
shown in this diagram. The potentiometers must be
wired on the basis of the colour assignment in line with
the specified diagram.
Fig. 9:
Lifting column without cover
1 "White" wire
2 "Brown" wire
3 "Green" wire
4 Potentiometers
5 Pinion
!
Incorrect wiring will destroy the potentiometers.
5.3.2
Testing potentiometers
Contents
Testing of potentiometers for values within
valid range.
Applicability
VLE 2130, VLE 2130 F, VLE 2130 E,
VLE 2130 EL, VLE 2140 EL
Selecting test function
1.
Set the encoding switch to position "7" and press
the Enter button.
If the value of the main column potentiometer is
within the valid range, LED1 flashes (green). If the
value is greater than 97 %, it flashes in red. If it is
less than 3 %, it flashes in orange.
If the value of the secondary column
potentiometer is within the valid range, LED2
flashes (green). If the value is greater than 97 %,
it flashes in red. If it is less than 3 %, it flashes in
orange.
Table 4 shows the entire operating range of the lifting
platform.
0.0
0.3
0.5
9.5
9.7
10.0
0 %
3 %
5 %
95 %
97 %
100 %
0.00 V
0.15 V
0.25 V
4.75 V
4.85 V
5.0 V
Schaden!
Untere
Grenze
Euro-Stop
Fußschutz
Obere
Grenze
Schaden!
LED
Spannung
weiß/grün
Poti
Umdr.
Vertikaler
Bereich
Position
Tab. 4:
Operating range of lifting platform
!
The lifting carriages must only move in the area
between 3 % and 97 % of the maximum operating
range. Otherwise mechanical damage could occur.
Содержание VLE 21 Series
Страница 1: ...VLE 21xx de Instandsetzungsanleitung 2 Säulen Hebebühne en Repair instructions 2 post lift ...
Страница 2: ...1 689 975 224 2013 11 06 Robert Bosch GmbH 2 VLE 21xx 2VLE 21xx de ...
Страница 26: ...1 689 975 224 2013 11 06 Robert Bosch GmbH 26 VLE 21xx Stromlaufplan de 12 4 2 VLE 2130 EL und VLE 2140 EL ...
Страница 27: ...1 689 975 224 2013 11 06 Robert Bosch GmbH Stromlaufplan VLE 21xx 27 de 12 4 3 VLE 2130 E ...
Страница 50: ...1 689 975 224 2013 11 06 Robert Bosch GmbH 50 VLE 21xx Circuit diagram en 12 4 2 VLE 2130 EL and VLE 2140 EL ...
Страница 51: ...1 689 975 224 2013 11 06 Robert Bosch GmbH Circuit diagram VLE 21xx 51 en 12 4 3 VLE 2130 E ...