58
en | Configuring the AutoDome 700 Series
AutoDome 700 Series IP PTZ Camera
F.01U.273.798 | 3.0 | 2012.08
User Manual
Bosch Security Systems, Inc.
Gateway address
If you want the unit to establish a connection to a remote location in a different subnet, enter
the IP address of the gateway here. Otherwise leave the box blank (
0.0.0.0
).
4.49.2
IPv6
Consult with the network administrator before making changes to the this section.
IP Address
Enter the desired IP address for the AutoDome 800 Series in this field. The IP address must
be valid for the network. A typical IPv6 address may resemble the following example:
2001:db8 : : 52:1:1
Consult the network administrator for valid IPv6 address construction.
Prefix Length
A typical IPv6 node address consists of a prefix and an interface identifier (total 128 bits). The
prefix is the part of the address where the bits have fixed values or are the bits that define a
subnet.
Gateway Address
If you want the unit to establish a connection to a remote location in a different subnet, enter
the IP address of the gateway here. Otherwise leave the box blank (
0.0.0.0
).
4.49.3
Detailed Settings
DNS server address
The AutoDome 800 Series is easier to access if the unit is listed on a DNS server. If you wish,
for example, to establish an Internet connection to the AutoDome 800 Series, it is sufficient to
enter the name given to the unit on the DNS server as a URL in the browser. Enter the IP
address of the DNS server here. Servers are supported for secure and dynamic DNS.
Video Transmission
If the unit is operated behind a firewall,
TCP (HTTP port)
should be selected as the transfer
protocol. For use in a local network, select
UDP
.
HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. If
you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In
this case, select
Off
.
HTTPS browser port
If you wish to allow browser access on the network via a secure connection, select an HTTPS
browser port from the list if necessary. The default HTTPS port is 443. Select the
Off
option
to deactivate HTTPS ports; only unsecured connections will now be possible.
The AutoDome 800 Series uses the TLS 1.0 encryption protocol. You may have to activate this
protocol via your browser configuration. You must also activate the protocol for the Java
applications (via the Java control panel in the Windows control panel).
CAUTION!
Multicast operation is only possible with the UDP protocol. The TCP protocol does not
support multicast connections.
The MTU value in UDP mode is 1,514 bytes.
Содержание VG5 700 Series
Страница 1: ...AutoDome 700 Series IP PTZ Camera VG5 700 Series en User Manual ...
Страница 2: ......
Страница 75: ...75 en Index AutoDome 700 Series IP PTZ Camera F 01U 273 798 3 0 2012 08 User Manual Bosch Security Systems Inc ...
Страница 76: ...AutoDome 700 Series IP PTZ Camera Index en 76 Bosch Security Systems Inc User Manual F 01U 273 798 3 0 2012 08 ...
Страница 77: ...77 en Index AutoDome 700 Series IP PTZ Camera F 01U 273 798 3 0 2012 08 User Manual Bosch Security Systems Inc ...
Страница 78: ...AutoDome 700 Series IP PTZ Camera Index en 78 Bosch Security Systems Inc User Manual F 01U 273 798 3 0 2012 08 ...
Страница 79: ...79 en Index AutoDome 700 Series IP PTZ Camera F 01U 273 798 3 0 2012 08 User Manual Bosch Security Systems Inc ...
Страница 80: ...80 en Index VG5 AutoDome Camera F 01U 265 794 1 0 2011 01 User s Manual Bosch Security Systems Inc ...
Страница 81: ......