50
en | Configuring the System
High-speed Positioning System
F.01U.164.491 | 2.0 | 2010.03
Installation Manual
Bosch Security Systems, Inc.
Note! Increase the reached speed from the default value to reach presets faster.
Note: *IR models are limited to 40 deg/s on pan
Patrol (preset tour)
The
Patrol
menu is a defined path from preset to preset. This can be from two (2) presets up
to 250. For example, the random option allows various presets such as preset 4, then
preset 1, then preset 8, then preset 3.
Feature
Description
Default
Options
HOME POSITION
Preset position associated with the home
function.
00001
00001 to 00250
REACHED SPEED
Speed for reaching the home position
when it is loaded.
20.0
.1 to 100.0*
PATROL MENU
> 1 - START POSITION
:
00001
2 - END POSITION
:
00250
3 - FIRST PRST SPEED
:
20.0
4 - RANDOM
:
NO
Feature
Description
Default
Options
START POSITION
The first preset position considered valid
for carrying out the patrol function.
00001
00001 to 00250
END POSITION
The last preset position considered valid
for carrying out the patrol function.
00250
00001 to 00250
FIRST PRST SPEED Speed at which the UPH reaches the first
preset position when the patrol function
is activated.
Increase the First PRST Speed from the
default value to reach presets faster.
20.0
01 to 100.0°*
RANDOM
Enables execution of the Patrol function
by passing through the defined positions
in a random manner. The random
sequence is continually recalculated.
NO
YES, NO
Note: *IR models are limited to 40 deg/s on pan