34
en | Configuring the Device
High-speed Positioning System
F.01U.164.491 | 2.0 | 2010.03
Installation Manual
Bosch Security Systems, Inc.
6
Configuring the Device
Before powering the High Speed Pan/Tilt, it must be properly configured. To configure the DIP
switches inside the configuration window, proceed as follows:
1.
Open the configuration window (as seen in
Figure 6.1
) by unscrewing the screws with a
3 mm Allen wrench.
2.
Verify that the position of the DIP switches are the same as in
Figure 6.1
.
Figure 6.1
Positioning the DIP Switches
–
For DIP switches (Reference 1-3
Figure 6.1
), when the rocker is down the switch is
OFF
or represents the logical value “0”; when the rocker is up, the switch is
ON
, with logical
value “1.”
–
For DIP switches (Reference 4-5
Figure 6.1
), when the rocker is up the switch is
OFF
or
represents the logical value “0”; when the rocker is down, the switch is
ON
, with logical
value “1.” The white rectangle represents the position of the rocker.
6.1
Factory Use Only
Leave all switches in the OFF position.
6.2
Protocol
There is no need to set any particular protocol, the UPH is auto-sensing. The protocols
supported are:
Reference
Description
1
Factory Use
2
Not Used, All Off
3
Address
4
RS485 Terminations
5
B Bilinx
Protocol
Baud Rate
Menu Setup (OSD)
Pelco D
2400 (8N 1)
Preset 95
Biphase and Bilinx
Auto
AUX-On 200
Содержание UPH Series