UHI/UHO Series UHO-HBPS-10, -50, and UHO-HPS-50 | en
27
Bosch Security Systems
User Manual
F.01U.026937 | V 2.0 | 2007.01
5
UHO-HBPS-10, -50, and UHO-HPS-50
5.1
Camera/lens wiring
Installation for these models is in accordance with
Section 4 Installation
, except as noted below.
All electrical power connections are made through the 4-pin
connector. Cable Requirements for the 4-pin connector:
6.0 mm (0.24 in) to 12.0 mm (0.47 in)
1.
Cut the power cord on 230 VAC camera models, leaving
enough cable for connection to the terminal block. Strip no
less than 6 mm (0.25 in) and no more than 8 mm (0.31 in)
of insulation away from the wire. Be sure not to nick the
wires.
2.
Insert the power cord through the back shell assembly and
strain relief. See
Figure 5.1
).
Fig. 5.1
Mating connector 4-pin assembly
!
CAUTION!
Use only 24 VAC power for UHO-HBPS-10 models.
These models have female connectors to prevent them from
being connected to the mating connector that is provided with
UHO-HPS-50 and UHO-HBPS-50 models that require 230 VAC.
Ensure that 230 VAC is not applied to the male mating
connector.
24 VAC ONLY!
Male clamping
ring
230 VAC ONLY!
Female clamping
ring
Internal strain
relief
Metal washer
Sealing gasket
Cable nut