24
en | Installation
UHI/UHO Series
F.01U.026937 | V 2.0 | 2007.01
User Manual
Bosch Security Systems
7.
On heater and heater/blower units, make sure the heater
and fan wires stay connected to the terminal block.
8.
Make sure the BNC cable is separated from the Mains
power and heater.
4.8
Video coax connection
See
Table 3.2
and
Table 3.4
for UHO-HBPS-10, UHO-HPS-50 and
UHO-HBPS-50 models.
1.
Install a 1/2-inch NPT fitting into the available hole in the
rear cap.
2.
Route the video coax cable through one of the fittings
installed in
Step 1.
, or one of the feed-through fittings in
the base.
3.
Attach the BNC connector to the coax and connect it to the
camera.
4.
Pull any excess wire out of the housing and tighten the fit-
ting to 8.5 Nm to 9.0 Nm (75 inch-lb to 80 inch-lb). This
torque rating is approximately one to one and a half turns
past the point where the fitting starts to grip the wire.
!
CAUTION!
For security protection of the device, the branch circuit
protection must be secured with a maximum fuse rating of 16A.
This must be in accordance with NEC 800 (CEC Section 60).
!
CAUTION!
Use only cables meeting specifications in
Section 4.3 Cable
requirements
for wiring video coax connections.
!
CAUTION!
Always securely tighten all fittings to ensure a liquid-
tight seal. Failure to do so could allow water to enter the
housing and damage the camera and lens. If a sealant is used,
be sure it is a neutral cure type. Sealants that release acetic
acid may harm camera electronics. Use of drip loops is
recommended on the wiring outside of the rear end cap.
Содержание UHI-OG-0
Страница 2: ......
Страница 10: ...10 en UHI UHO Series docnumber V 2 0 2007 01 User Manual Bosch Security Systems ...
Страница 31: ......