14
en | Installation
UHI/UHO Series
F.01U.026937 | V 2.0 | 2007.01
User Manual
Bosch Security Systems
4.3
Cable requirements
4.3.1
Video transmission (coaxial)
4.3.2
Input power cord
Cable type
runs < 300m (1000 ft)
runs < 600m (2000 ft)
RG-59/U
RG-11/U
Cable diameter (outer)
4.6 mm to 7.9 mm
(0.18 in to 0.31 in)
Cable shape
Round
Cable shield
>93% braided copper
Center conductor
Stranded or solid copper
DC resistance
RG-59/U
RG-11/U
<15 ohm/1000 m
<6 ohm/1000 m
Cable impedance
75 ohm
Certificating authority
UL
Environmental
Outdoor rated
Temperature rating
+80 °C (+176 °F) or greater
Reference type
Belden 9259
Table 4.2
Video cable specifications
Cable type
3 x 18 AWG
Cable diameter (outer)
4.6 to 7.9 mm
(0.18 to 0.31 in)
Cable shape
Round
Conductors
3 or 2
Voltage rating
300 V
Certificating authority
UL/C.S.A., UL VW-1
Environmental
Outdoor rated
Temperature rating
+105° C (+221° F) or greater
Reference type
Belden 19509, 3-conductor;
Northwire FSJT183-81K, 3-conduc-
tor
Table 4.3
Power cord specifications for North America