background image

 

6 720 220 380

Subject to change without prior notice                                      Revised 06-13

14

TSTBT4H2CP SERIES

period has two set points, one for Cooling Mode and one 
for Heating Mode.

1.   From the thermostat home screen, press menu twice 

or “Schedule” to enter the Programming Setup Menu.

2.   morn is the first time period displayed.

3.   Use the 

 

or

 

 button to adjust the start time for 

the current time period. The time duration is in 15 
minute intervals.

4.   Push neXT.

5.   Set the set point for the Heating mode using the 

 

or

 

 button. You will see “Heat” beneath the set 

point temperature.

6.   Push neXT.

7.   Set the set point for the Cooling mode using the 

 

or

 

 button. You will see “Cool” beneath the set point 

temperature.

8.   Push neXT.

9.   The next time period is now displayed.

10.  Repeat steps 3-8 to establish the start time for that 

time period and the heating and cooling set points for 
that time period.

11.  Push neXT.

The current screen at this point is used to assign the 
current schedule being established to specific days.

7 day ProGram sChedule
(ConTinued from sChedule 

ProGramminG)

The time schedule and set points have been determined, 
but they have not been assigned to specific day at this 
point.

The default setting for the TSTBT4H2CP Thermostat 
Series is a 7 Day Schedule. All 7 days are displayed. All 7 
days will utilize the schedule just created if no changes 
are made at this point.

12.  Press enTer to apply the schedule just created to all 

7 days of the week.

CusTom ProGram sChedule
(ConTinued from sChedule 

ProGramminG)

Some days may require a different schedule program; 
whether it be a different time period definition or different 
heating / cooling set points. To create specific schedules 

for specific days, continue from the Schedule 
Programming Steps 1-11 from above and continue with the 
following instructions. Each day can have its own unique 
programmed schedule and set points; for a total of 7 
possible unique schedules for the TSTBT4H2CP 
Thermostat Series. 

The decision to be made here is what days the scheduled 
program will be assigned to; this is accomplished by 
removing the days that the program will not be associated 
with. The remaining days being displayed are the days that 
the current schedule will be assigned to.

Picking up after step 11 from above:

Currently all 7 days are being displayed and an “01” is 
displayed in the u   day. By pressing the 

 

or

 

 button, 

you will see “Mon” appear or disappear. This is how you 
add or remove Monday from the current schedule 
program. The 

 button adds “Mon” to the list of days 

affected, the 

 button removes “Mon” from the list of 

days affected.

Creating a 5+2 Schedule Example (Weekday Sc 
Weekend Schedule):

13. Press the neXT button until “06” is displayed in the 

upper right hand corner (Day 6 which is Saturday).

14. Press the 

 button to remove “Sat” from the days 

being displayed.

15. Press the neXT button to change the day number to 

“07” (Day 7 is Sunday).

16. Press the 

 button to remove “Sun” from the days 

being displayed.

17. Currently you should only see Mon, Tue, Wed, Thu, Fri 

being displayed.  Press enTer button.

You should now be back to the thermostat home screen 
and the schedule that was just created has been applied 
to Mon-Fri.

18. Repeat Steps 1-11 from above establishing times and 

set points to apply for the weekend (Sat & Sun).

19. All days should be displayed and “01” should be in the 

upper right hand corner. Press the 

 button to 

remove “Mon” from the days being displayed.

20. Press the neXT button to change the day number to 

“02” (Day 2 is Tuesday).

21. Press the 

 button to remove “Tue” from the days 

being displayed.

7 day Program schedule

Содержание TSTBT4H2CP-M--A

Страница 1: ...Owner s Manual Thermostat Series Bosch Communicating Thermostats TSTBT4H2CP Series TSTBT4H2CP M A TSTBT4H2CPHM A 6 720 220 380 Revised 06 13 ...

Страница 2: ...ze Condition Alert 10 Condensate Line Alert 10 Brownout Alert 10 Evaporator Freeze Alert 10 Lost Equipment Communication 11 Lost Gateway Communication 11 Low Heating Output 11 Low Cooling Output 11 Lost Power 11 Initial Thermostat Settings 12 Selecting Heating or Cooling 12 Selecting Auto or Cont Fan 12 Adjusting the Temperature Setting 12 Adjusting RH Setpoints for Humidity Control 12 Selecting O...

Страница 3: ... not used Four schedules per day 7 day programmable Up to four stage heating and 2 stage cooling Optional automatic fan operation during daytime on selected days Compatible with conventional and dual fuel heatpumps and gas electric systems Optional temperature sensors for dis charge air temperature and outdoor air temperature Optional remote space temperature sensors Diagnostic monitor indicates e...

Страница 4: ...W A model Fan key selectsAutomatic or On Previous key when in programming mode quick reference MENU MODE NEXT ENTER buttons change functionalities during programming or other type of menu setting changes Their function is described for that specific function within the Tech Setup Section Insid e We Day HEAT Schedule AUTO FAN MENU MODE NEXT ENTER Heat Set To SYSTEM AM Displays heating cooling or RH ...

Страница 5: ...used as remote space temperature sensors See Installer options 13 and 14 A 4 wire thermostat cable between the Receiving Module and the Thermostat provides Modbus communication using RS485 The HUM terminal can be used to control de humidification using the cooling or hot gas reheat These terminals are used to control a humidifier The PDU terminal is used to monitor Bosch equipment and indicate any...

Страница 6: ...e module Then push gently until the thermostat or base module Caution To insure a solid fit between the thermostat and the subbase 1 Mount subbase to a flat wall 2 Use screws provided 3 Drywall anchors should be flush with the wall 4 Wires should be pushed into the wall insTallinG The Trm reCeivinG module TRM stands for Transmitting and Receiving Module The TRM communicates with the TSTBT4H2CP Thermo...

Страница 7: ...type being transmitted will be displayed on the thermostat Do not use with any other equipment TSTBT4H2CP Thermostat Series Wiring Notes Bosch Water Source Heat Pumps utilize O type reversing valve operation If your heat pump utilizes B type reversing valve operation substitute the wiring for the O terminals for B TemPeraTure sensor ConneCTions zonb las m a return air Temperature sensor Optionally...

Страница 8: ...erature Sensor 2 When both TS 1 and TS2 are used as remote space temperature sensors both sensor readings will be averaged with the thermostat sensor reading See the available accessories at the end of this manual for compatibility part numbers and descriptions for ordering Remove the Battery Tab The TSTBT4H2CP M A Thermostat Series has a coin cell battery for maintaining the clock schedules and u...

Страница 9: ...lays the associated fault to be displayed on the thermostat enablinG faulT Code messaGes Run a low voltage wire from the ALR OUT terminal connection on the UPM board to the PDU terminal on the TRM This feature is only available with a Florida Heat Pump or Bosch Heat Pump See page 8 for wiring diagram disPlayinG equiPmenT serviCe messaGes The word Message will blink anytime an equipment service mes...

Страница 10: ...R SYSTEM CondensaTe line alerT The equipment has detected a condensate line blockage condition and prohibited cooling calls Contact yourlocal contractor for service Press the enTer key to return to normal thermostat display Message HEAT AUTO FAN MENU MODE NEXT ENTER SYSTEM brownouT alerT The equipment has detected a power brownout condition and prohibited heating and cooling calls Contact yourloca...

Страница 11: ...eing utilized See the Tech Menu Setup Explanation for more information The thermostat has detected the heating equipment output is below its limit This can be caused by unusually severe cold weather If the condition persists contact your local contractor for service Press the ENTER key to return to normal thermostat display Message HEA T AUT O FA N MENU MODE NEXT ENTER SYSTEM Low Cooling Output Th...

Страница 12: ...temperature ie Heat will be displayed when establishing the set point for heating Inside We Day HEAT Schedul e AUTO FAN MENU MODE NEXT ENTER Heat Set To SYSTEM AM Up Down Keys Adjusting RH Setpoints for Humidity Control Only available with TSTBT4H2CPHM A TSTBT4H2CPHMW A model thermostats If a thermostat has an RH sensor use the NEXT key to select RH setting for dehumidification or humidifier contr...

Страница 13: ...nd day of the week can be set using the menu key or by pressing AM PM key area shown in gray Inside We Day HEAT Schedul e AUTO FAN MENU MODE NEXT ENTER Heat Set To SYSTEM AM Press here to change time of day Menu Key 1 Press the AM or PM text or menu button once 2 Use the or button to adjust the hour of day Caution Pay attention to ensure the PM or AM is set correctly 3 Push neXT to proceed to set ...

Страница 14: ...c days continue from the Schedule Programming Steps 1 11 from above and continue with the following instructions Each day can have its own unique programmed schedule and set points for a total of 7 possible unique schedules for the TSTBT4H2CP Thermostat Series The decision to be made here is what days the scheduled program will be assigned to this is accomplished by removing the days that the prog...

Страница 15: ...K and hold for 2 seconds the screen shot below will be displayed 2 Push the button until the two digit code is displayed in the upper right hand corner see the screen shot below 3 Press enTer Caution The Cancel key blank key second from the left can be pushed at any time to cancel out of the sequence and will return to the home screen without changes saved To Unlock the Thermostat 1 Push loCKed an...

Страница 16: ...orn 6 a m 70 F 21 C 78 F 26 C Day 8 a m 62 F 17 C 85 F 29 C Eve 6 p m 70 F 21 C 78 F 26 C Night 10 p m 62 F 17 C 82 F 28 C Sunday Morn 6 a m 70 F 21 C 78 F 26 C Day 8 a m 62 F 17 C 85 F 29 C Eve 6 p m 70 F 21 C 78 F 26 C Night 10 p m 62 F 17 C 82 F 28 C use the table below to plan your customized program schedule if using 5 1 1 Custom User Schedule Day of the Week Time Period Time Setpoint Events ...

Страница 17: ...t point temperature within the minimum off time the equipment will not come on This is a protection feature for the compressor and is normal Wait 10 min and verify if equipment has began operating in heating or cooling mode If unit remains off call a licensed technician 5 Heating comes on during a cooling call with a heat pump The thermostat is not set up correctly for a heat pump Call a technicia...

Страница 18: ...perate a heat pump Thermostat was not set correctly by the technician please contact local technician 17 Heat Pump is in cooling mode when thermostat is in heating mode or vise a versa O terminal is being used when the B terminal should be or vise a versa Thermostat was no installed correctly please contact local technician 18 The thermostat setpoint is not satisfied yet there is no heating or coo...

Страница 19: ...ment of the defective component or part 7 Electricity or fuel costs or any increases or unrealized savings in same for any reason whatsoever 8 Damage caused by excessive temperatures or pressures fuel or gas explosion electrochemical reaction water and air impurities electrical failures use during construction flooding or acts of God 9 Any damage or failure resulting from the introduction of harmf...

Страница 20: ...or only the unexpired tem of the original warranty n Some states do not allow the exclusion of limitation of damages or limitations on how long an implied warranty lasts so the above limitations and exclusions may not apply to you warranTy Claims ProCess If you have a warranty claim you should notify the contractor who installed your Product and ask that the contractor notify FHP Manufacturing Com...

Страница 21: ...6 720 220 380 Revised 06 13 Subject to change without prior notice TSTBT4H2CP SERIES 21 ...

Страница 22: ...6 720 220 380 Subject to change without prior notice Revised 06 13 22 TSTBT4H2CP SERIES ...

Страница 23: ...6 720 220 380 Revised 06 13 Subject to change without prior notice TSTBT4H2CP SERIES 23 ...

Страница 24: ...601 N W 65th Court Ft Lauderdale FL 33309 Phone 866 642 3198 Fax 954 776 5529 www bosch climate us ...

Отзывы: