7.1.3 Grinding
unit
Complaint
Cause?
Remedial action
►
Grinding unit has not been adequately filled with
coffee
Coffee beans are not ground
►
Coffee beans are too oily and stick to the wall of
the bean container
►
Coffee beans do not fall into the grinding unit
►
Press coffee dispensing button again to start
another brewing process
►
Empty and clean bean container. Use beans
with lower fat content
Noise of grinding unit is
quieter and higher
►
Bean container is empty
►
Fill bean container
►
Coffee beans do not fall into the grinding unit, are
too oily and stick to the wall of the bean container
►
Empty and clean bean container. Use beans
with lower fat content
Noise of grinding unit is loud
►
Foreign object in grinding unit (e.g. grit, may also
occur with select coffees)
►
Replace grinding unit
Grinding unit is not
functioning
►
Ground coffee has been selected
►
Press coffee dispensing button again to start
another brewing process
►
Power module not actuated by the logic module
►
Check actuation; to do this, press the coffee
dispensing button to start a brewing
process. If required, replace logic module
►
Grinding unit not actuated by the power module
►
Check actuation; to do this, press the coffee
dispensing button to start a brewing
process. If required, replace power module
►
Grinding unit motor defective
►
Replace grinding unit
Grinding unit starts as soon
as appliance is switched on
►
Optocoupler on power module defective
►
Replace power module