Consumer Options 3
Item
Location
Option
Default New
Consumer Options 3
0498
1 = Codepad fault beeps allowed
2 = Use digit 3 for codepad duress alarm
(instead of digit 9)
4 = Alarms activate sirens and strobe outputs
in STAY Modes 1 and 2
8 = Zone tamper alarms to be silent
5
1 – Codepad Fault Alarms Beep
If this option is selected, the FAULT indicator flashes and the codepad beeps once every
minute until the user acknowledges a system fault. To acknowledge a new fault and stop the
codepad from beeping once every minute, press [AWAY].
If this option is not selected, the codepad only the FAULT indicator flashes when a new fault
occurs and the codepad does not beep once every minute.
2 – Digit 3 for Codepad Duress Instead of 9
If this option is selected, a user can add 3 (instead of a 9) to the code used to disarm the
system to activate a Duress Alarm.
4 – Alarms Activate Sirens and Strobe Outputs in STAY Modes 1 and 2
Select this option if audible alarms are required when the system is armed in STAY Mode 1 or
STAY Mode 2.
8 – Zone Tamper Alarms To Be Silent
This option allows Tamper Alarms, when Option 15 is programmed in Location 266 (refer to
EOL Resistor Value, page 92), or Tamper Alarms on RF wireless devices to be silent when
activated.
18.8
Control Panel
System and Consumer Options | en 143
Bosch Security Systems, Inc.
Installation Guide
2017.10 | 03 | F.01U.298.026