EOL Resistor Value
Location 266
0
No EOL
1
1K (brown, black, red)
2
1K5 (brown, green, red)
3
2K2 (red, red, red)
4
3K3 (orange, orange, black, brown) 1%
5
3K9 (orange, white, red)
6
4K7 (yellow, violet, red)
7
5K6 (green, blue, red)
8
6K8 (blue, grey, black, brown) 1%
9
10K (brown, black, orange)
10
12K (brown, red, orange)
11
22K (red, red, orange)
12
Normal open
13
Reserved
14
Split EOL (3K3/6K8) with tamper (1K)
15
Split EOL 1% resistors
You can program the control panel for different end-of- line (EOL) resistor values. This is a
global parameter that affects all zones simultaneously. This feature allows you to install the
control panel at an existing site without changing the EOL resistors. This feature also
increases the security of the system because eleven possible EOL resistor values can be used,
which makes it extremely difficult to tamper with the system.
For No EOL, it is short as normal status and it is unsealed when the system activates an alarm.
Connections for EOL Resistors
13.2
92
en | Zone Information
Control Panel
2017.10 | 03 | F.01U.298.026
Installation Guide
Bosch Security Systems, Inc.